Johansson, Magnus C, 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för akut och kardiovaskulär medicin,Institute of Medicine, Department of Emergeny and Cardiovascular Medicine
Eriksson, Peter J, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för akut och kardiovaskulär medicin,Institute of Medicine, Department of Emergeny and Cardiovascular Medicine
Guron, Cecilia Wallentin, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för akut och kardiovaskulär medicin,Institute of Medicine, Department of Emergeny and Cardiovascular Medicine
visa fler...
Dellborg, Mikael, 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för akut och kardiovaskulär medicin,Institute of Medicine, Department of Emergeny and Cardiovascular Medicine
visa färre...
 (creator_code:org_t)
2010
2010
Engelska.
Ingår i: Journal of the American Society of Echocardiography. - 0894-7317. ; 23:11, s. 1136-1142
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Contrast injections during transesophageal echocardiography for patent foramen ovale (PFO) detection may be false negative. The characteristics of false-negative injections were studied retrospectively. METHODS: Contrast transesophageal echocardiography was analyzed for the presence or absence of two characteristics: leftward bulging of the interatrial septum and dense contrast filling of the region of the right atrium adjacent to the interatrial septum. RESULTS: Two hundred forty-seven injections were administered to 14 patients with PFOs, and 130 (53%) were false negative. The absence of either characteristic during a single injection resulted in low sensitivity for PFO detection of 7%. When the two characteristics were present at the same time, the sensitivity for PFO detection after a single injection was as high as 95%. CONCLUSIONS: The simultaneous presence of both leftward bulging of the interatrial septum and dense contrast filling of the region in the right atrium, adjacent to the interatrial septum, is a prerequisite for PFO detection, and if either characteristic is missing, the injection is inconclusive.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Transesophageal echocardiography; Contrast echocardiography; Heart septal defects; Patent foramen ovale; False-negative reaction

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy