SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Hagberg Kerstin)
 

Search: WFRF:(Hagberg Kerstin) > Apparatus for monit...

Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study

Frossard, L. (author)
Gow, D. L. (author)
Hagberg, Kerstin, 1957 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
show more...
Cairns, N. (author)
Contoyannis, B. (author)
Gray, S. (author)
Brånemark, Rickard, 1960 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Pearcy, M. (author)
show less...
 (creator_code:org_t)
Elsevier BV, 2010
2010
English.
In: Gait & Posture. - : Elsevier BV. - 1879-2219 .- 0966-6362. ; 31:2, s. 223-228
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by four-fold anteriorly and 14-fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by nine-fold laterally and 16-fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17% and 83% of the trials, respectively, by up to + or - 10%. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Rehabilitation; Lower limb amputation; Osseointegration; Load bearing; Force sensor

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view