SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Popovic Zoran 1966)
 

Sökning: WFRF:(Popovic Zoran 1966) > (2010-2014) > Noninvasive imaging...

Noninvasive imaging of human foveal capillary network using dual-conjugate adaptive optics.

Popovic, Zoran, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
Knutsson, Per, 1978 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
Thaung, Jörgen, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
visa fler...
Owner-Petersen, Mette (författare)
Lund University,Lunds universitet,Astronomi - Genomgår omorganisation,Institutionen för astronomi och teoretisk fysik - Genomgår omorganisation,Naturvetenskapliga fakulteten,Lund Observatory - Undergoing reorganization,Department of Astronomy and Theoretical Physics - Undergoing reorganization,Faculty of Science
Sjöstrand, Johan, 1936 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation
visa färre...
 (creator_code:org_t)
Association for Research in Vision and Ophthalmology (ARVO), 2011
2011
Engelska.
Ingår i: Investigative ophthalmology & visual science. - : Association for Research in Vision and Ophthalmology (ARVO). - 1552-5783. ; 52:5, s. 2649-55
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To demonstrate noninvasive imaging of human foveal capillary networks with a high-resolution, wide-field, dual-conjugate adaptive optics (DCAO) imaging instrument. METHODS: The foveal capillary networks of five healthy subjects with no previous history of ocular or neurologic disease or surgery were imaged with a novel high-resolution, wide-field DCAO instrument. The foveal avascular zone (FAZ) in each image was defined using a manual procedure. An automated algorithm based on publicly available and custom-written software was used to identify vessels and extract morphologic FAZ and vessel parameters. Capillary densities were calculated in two annular regions of interest (ROIs) outside the FAZ (500 μm and 750 μm outer radius from the foveal center) and in the superior, inferior, temporal, and nasal quadrants within the two ROIs. RESULTS: Mean FAZ area was 0.302 ± 0.100 mm(2), and mean capillary density (length/area) in the inner ROI was 38.0 ± 4.0 mm(-1) and 36.4 ± 4.0 mm(-1) in the outer ROI. The difference in ROI capillary density was not significant. There was no significant difference in quadrant capillary density within the two ROIs or between quadrants irrespective of ROI. CONCLUSIONS: The authors have demonstrated a technique for noninvasive imaging and semiautomated detection and analysis of foveal capillaries. In comparison with other studies, their method yielded lower capillary densities than histology but similar results to the current clinical gold standard, fluorescein angiography. The increased field of view of the DCAO instrument opens up new possibilities for high-resolution noninvasive clinical imaging of foveal capillaries.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Nyckelord

Adult
Capillaries
anatomy & histology
Diagnostic Imaging
instrumentation
Diagnostic Techniques
Ophthalmological
Fovea Centralis
blood supply
Humans
Middle Aged
Optics and Photonics
instrumentation
Retinal Vessels
anatomy & histology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy