SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Andersson Torsten)
 

Sökning: WFRF:(Andersson Torsten) > Long-Term Follow-Up...

Long-Term Follow-Up of CeraOne Single-Implant Restorations: An 18-Year Follow-Up Study Based on a Prospective Patient Cohort.

Bergenblock, Sibel, 1973 (författare)
Andersson, Bernt, 1939 (författare)
Fürst, Björn, 1966 (författare)
visa fler...
Jemt, Torsten, 1950 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
visa färre...
 (creator_code:org_t)
2010-06-25
2012
Engelska.
Ingår i: Clinical implant dentistry and related research. - : Wiley. - 1708-8208 .- 1523-0899. ; 14:4, s. 471-479
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ABSTRACT Background: Knowledge on long-term clinical performance of more than 5 years on the single-implant CeraOne (Nobel Biocare AB, Gothenburg, Sweden) concept is limited. Purpose: The aim of this study is to report the long-term clinical performance of the first CeraOne single-implant restorations, installed 17 to 19 years ago. Materials and Methods: The group comprised 57 patients provided with 65 CeraOne single-tooth restorations. Sixty-two all-ceramic and three metal-ceramic crowns were cemented between 1989 and 1991. Patients were followed up clinically and with intraoral radiographs at placement, after 1, 5, and between 17 and 19 years after placement. Results: Data were available for altogether 48 patients, followed up on an average time of 18 years. Excluding deceased patients (n = 2) and failed implant patients (n = 2), only five patients were lost to follow-up (8.8%). Two implants failed, resulting in an 18-year implant cumulative success rate (CSR) of 96.8%, and altogether eight original single-crown restorations were replaced (CSR 83.8%). The most common reason for crown replacement was infra-position of the implant crown (n = 3). Many of the remaining original crowns showed various signs of implant crown infraposition at the termination of the study. In general, the soft tissue at the restorations was assessed to be healthy and comparable with the gingiva at the adjacent natural teeth. Bone levels were on an average stable with only few patients exhibiting bone loss of more than 2 mm during 18 years in function. Conclusion: This long-term follow-up study of single-implant restorations shows encouraging results with few implant failures and minimal bone loss over an 18-year period. Original single-crown restorations were replaced more frequently, because of, for example, implant crown infraposition and veneer fractures. The CeraOne concept proved to be a highly predictable and safe prosthodontic treatment.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

entand
uppföljning
implantat

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy