SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2191 219X
 

Sökning: L773:2191 219X > Microdosimetric ana...

Microdosimetric analysis of 211At in thyroid models for man, rat and mouse.

Josefsson, Anders, 1971 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Forssell-Aronsson, Eva, 1961 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: EJNMMI research. - 2191-219X. ; 2:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ABSTRACT: BACKGROUND: The alpha particle emitter 211At is proposed for therapy of metastatic tumour disease. 211At is accumulated in the thyroid gland in a similar way as iodine. Dosimetric models of 211At in the thyroid are needed for radiation protection assessments for 1) patients receiving 211Atlabelled pharmaceuticals where 211At may be released in vivo and 2) personnel working with 211At. Before clinical trials, preclinical studies are usually made in mice and rats. The aims of this study were to develop thyroid models for mouse, rat and man, and to compare microdosimetric properties between the models. METHODS: A thyroid follicle model was constructed: a single layer of 6 to 10-mum thick follicle cells with centrally positioned 4 to 8 mum (diameter) spherical nuclei surrounded a 10 to 500 mum (diameter) spherical follicle lumen. Species-specific models were defined for mouse, rat and man. The source compartments for 211At were the follicle lumen, follicle cells and follicle cell nuclei. The target was the follicle cell nucleus. Simplified species-specific thyroid models were used to investigate the contribution from surrounding follicles. Monte Carlo simulations were performed using the general purpose radiation transport code MCNPX 2.6.0. RESULTS: When 211At was homogeneously distributed within the follicle lumen, the mean specific energies per decay, z, to the follicle cell nucleus were 2.0, 1.1 and 0.17 mGy for mouse, rat and man, respectively. Corresponding values for the single-hit mean specific energy per decay, z1, were 1.3, 0.61 and 0.37 Gy. Assuming a homogeneous 211At concentration in the follicle lumen, <0.5%, 7%, and 45% of the emitted alpha particles were fully stopped within the follicle lumen for the respective models. CONCLUSIONS: The results clearly show the influence of the follicle size, alpha particle range and 211At location within the thyroid follicle on the dosimetric parameters. Appropriate thyroid models are required for translation of dosimetric parameters between species.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Josefsson, Ander ...
Forssell-Aronsso ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
EJNMMI research
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy