Search: WFRF:(Gröndahl Hans Göran 1940) >
Sleeping implant in...
-
Granström, Gösta,1950Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology
(author)
Sleeping implant in the temporal bone: report of a case with 20-year follow-up.
- Article/chapterEnglish2012
Publisher, publication year, extent ...
Numbers
-
LIBRIS-ID:oai:gup.ub.gu.se/160867
-
https://gup.ub.gu.se/publication/160867URI
-
https://doi.org/10.1111/j.1708-8208.2009.00245.xDOI
Supplementary language notes
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
Background: There is limited knowledge of the long-term fate of “sleeping” or nonloaded implants in the temporal bone. Purpose: This article describes the fate of a fixture installed in the temporal bone that remained unloaded for 20 years. Patient and Methods: A 25-year-old male with hemifacial microsomia had three osseointegrated implants installed for an auricular episthesis and bone-anchored hearing aid (BAHA) in the left temporal bone in 1988. Two of the implants for the ear episthesis were activated the same year, but the fixture for the hearing aid was not uncovered until 2008. When the patient experienced hearing problems at his office, he wanted to reactivate the sleeping implant. An audiogram showed a maximum conductive hearing loss with good preserved cochlear function. Before reactivation, an Accuitomo three-dimensional, cone beam computed tomography was performed. Resonance frequency analysis (RFA) using the Ostell technique was done when the implant was uncovered. Results: Preoperative x-ray investigation showed the sleeping implant to be well integrated in the temporal bone, covered with 1 mm bone, and with no signs of resorption. Geometric measurements correlating to the two loaded implants showed the sleeping implant to be positioned too close to these to be able to anchor a BAHA without interference with the episthesis. Surgical exploration was done to analyze the implant. The clinical status correlated well to that diagnosed from the x-ray investigation. RFA revealed the implant to be well integrated. A new fixture and abutment for BAHA was installed in the temporal line and activated 2 months after surgery. The patient is today supplied with a BAHA. Conclusion: It seems possible to use sleeping implants in the temporal bone even 20 years after installation.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Gröndahl, Hans-Göran,1940Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology(Swepub:gu)xgroha
(author)
-
Tjellström, Anders,1937
(author)
-
Göteborgs universitetInstitutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar
(creator_code:org_t)
Related titles
-
In:Clinical implant dentistry and related research: Wiley14:2, s. 236-401708-82081523-0899
Internet link
Find in a library
To the university's database