SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Fletcher John)
 

Sökning: WFRF:(Fletcher John) > Peptide structural ...

Peptide structural analysis using continuous Ar cluster and C60 ion beams

Aoyagi, Satoka (författare)
Fletcher, John S. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology,University of Gothenburg
Sheraz, Sadia (författare)
visa fler...
Kawashima, Tomoko (författare)
Berrueta Razo, Irma (författare)
Henderson, Alex (författare)
Lockyer, Nicholas P (författare)
Vickerman, John C (författare)
visa färre...
 (creator_code:org_t)
2013-07-09
2013
Engelska.
Ingår i: Analytical and Bioanalytical Chemistry. - : Springer Science and Business Media LLC. - 1618-2642 .- 1618-2650. ; 405:21, s. 6621-6628
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A novel application of time-of-flight secondary ion mass spectrometry (ToF-SIMS) with continuous Ar cluster beams to peptide analysis was investigated. In order to evaluate peptide structures, it is necessary to detect fragment ions related to multiple neighbouring amino acid residues. It is, however, difficult to detect these using conventional ToF-SIMS primary ion beams such as Bi cluster beams. Recently, C60 and Ar cluster ion beams have been introduced to ToF-SIMS as primary ion beams and are expected to generate larger secondary ions than conventional ones. In this study, two sets of model peptides have been studied: (des-Tyr)-Leuenkephalin and (des-Tyr)-Met-enkephalin (molecular weights are approximately 400 Da), and [Asn1 Val5]-angiotensin II and [Val5]-angiotensin I (molecular weights are approximately 1,000 Da) in order to evaluate the usefulness of the large cluster ion beams for peptide structural analysis. As a result, by using the Ar cluster beams, peptide molecular ions and large fragment ions, which are not easily detected using conventional ToF-SIMS primary ion beams such as Bi3+, are clearly detected. Since the large fragment ions indicating amino acid sequences of the peptides are detected by the large cluster beams, it is suggested that the Ar cluster and C60 ion beams are useful for peptide structural analysis.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Continuous Ar cluster beam . ToF-SIMS . Peptide structure . (des-Tyr)-enkephalin . Angiotensin
Continuous Ar cluster beam . ToF-SIMS . Peptide structure . (des-Tyr)-enkephalin . Angiotensin

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy