SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hagberg Kerstin)
 

Sökning: WFRF:(Hagberg Kerstin) > Load applied on bon...

Load applied on bone-anchored transfemoral prosthesis: Characterization of a prosthesis-A pilot study

Frossard, L. (författare)
Häggström, Eva (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Hagberg, Kerstin, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
visa fler...
Brånemark, Rickard, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
visa färre...
 (creator_code:org_t)
Journal of Rehabilitation Research & Development, 2013
2013
Engelska.
Ingår i: Journal of Rehabilitation Research and Development. - : Journal of Rehabilitation Research & Development. - 0748-7711. ; 50:5, s. 619-634
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The objectives of this study were to (1) record the inner-prosthesis loading during activities of daily living (ADLs), (2) present a set of variables comparing loading data, and (3) provide an example of characterization of two prostheses. The load was measured at 200 Hz using a multi-axial transducer mounted between the residuum and the knee of an individual with unilateral transfemoral amputation fitted with a bone-anchored prosthesis. The load was measured while using two different prosthetic knees, mechanical (PRO1) and microprocessor-controlled (PRO2), during six ADLs. The characterization of the prostheses was achieved using a set of variables split into four categories, including temporal characteristics, maximum loading, loading slopes, and impulse. Approximately 360 gait cycles were analyzed for each prosthesis. PRO I showed a cadence improved by 19% and 7%, a maximum force on the long axis reduced by 11% and 19%, and an impulse reduced by 32% and 15% during descent of incline and stairs compared with PRO2, respectively. This work confirmed that the proposed apparatus and characterization can reveal how changes of prosthetic components are translated into inner-prosthetic loading.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)

Nyckelord

activity of daily living
artificial limb
bone-anchorage
gait
impulse
loading
osseointegration
TRANS-FEMORAL AMPUTEE
KNEE-JOINTS
OSSEOINTEGRATED FIXATION
AMPUTATION
PROSTHESES
GAIT ANALYSIS
DAILY-LIFE
WALKING
LIMB
REHABILITATION
PERFORMANCE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Frossard, L.
Häggström, Eva
Hagberg, Kerstin ...
Brånemark, Ricka ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Sjukgymnastik
Artiklar i publikationen
Journal of Rehab ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy