Inducible Displacements of the Cup and the Femoral Head During Active Range of Motion: Dynamic RSA Studies of Cemented Total Hip Replacements

Digas, Georgios, 1963 (författare)
Johanson, Per-Erik (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Kärrholm, Johan, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
 (creator_code:org_t)
2013-08-12
2013
Engelska.
Ingår i: Journal of Orthopaedic Research. - : Wiley. - 0736-0266. ; 31:11, s. 1686-1693
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We evaluated changes in position of the femoral head relative to the cup and of the cup relative to the pelvis in total hip replacement patients during hip motion 2 years postoperatively. Two patient groups with nine patients in each group were studied. Hip motions, translations of the femoral head center, and cup displacements were recorded with dynamic radiostereometric examination (RSA, 2exposures/s) during abduction in Group 1 and with use of static RSA exposures at increasing flexion of the hip in Group 2. Conventional radiographic examinations were used to evaluate any radiolucent lines around the cups at 2 years. During active abduction the femoral head center moved medially (median 0.04mm) and the cup tilted anteriorly (median 0.09mm). Increments in radiolucent lines at 2 years correlated to medial femoral head penetration, posterior tilt, and retroversion of the cup at 20 degrees of abduction. The extension of radiolucent lines at 2 years showed a positive correlation with proximal inducible displacement of the cup and posterior translation of the femoral head center at maximum hip flexion. Our observations may be of value in understanding the pathogenesis of the loosening process and may be used to facilitate the development of prosthetic designs that optimize hip kinematics. (c) 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1686-1693, 2013

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

dynamic radiostereometric analysis
femoral head and cup displacement
IN-VIVO DETERMINATION
POLYETHYLENE
ARTHROPLASTY
IMPINGEMENT
SEPARATION
WEAR
LEE JG
1976
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
P20

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Digas, Georgios, ...
Johanson, Per-Er ...
Kärrholm, Johan, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Journal of Ortho ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy