SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Johansson Birgitta 1960)
 

Sökning: WFRF:(Johansson Birgitta 1960) > Low Mortality and L...

Low Mortality and Low Rate of Perceived and Documented Arrhythmias after Cox Maze III Surgery for Atrial Fibrillation.

Johansson, Birgitta, 1960 (författare)
Väärt, Oskar, 1976 (författare)
Edvardsson, Nils, 1942 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
visa fler...
Nyström, Britta M (författare)
Scherstén, Henrik, 1956 (författare)
Karlsson, Thomas, 1956 (författare)
Berglin, Eva, 1947 (författare)
visa färre...
 (creator_code:org_t)
2013-11-15
2014
Engelska.
Ingår i: Pacing and clinical electrophysiology : PACE. - : Wiley. - 1540-8159 .- 0147-8389. ; 37:2, s. 147-156
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: To report a long-term single-site experience of the cut-and-sew Cox maze III procedure for atrial fibrillation (AF). Methods: A total of 232 consecutive patients underwent the Cox maze III procedure for symptomatic therapy-refractory AF, with concomitant surgery in 34 patients. Follow-up data were obtained from electrocardiograms, patient visits, questionnaires, and medical files. Results: There were 103 patients (44%) with paroxysmal AF during 8.8 ± 6.5 years and 129 patients (56%) with nonparoxysmal AF for 7.3 ± 6.7 years. The preoperative New York Heart Association class was better in patients with paroxysmal AF (P < 0.0001); the left ventricular ejection fraction was 59 ± 7% versus 56 ± 8%, P = 0.003, and the left atrial area 24 ± 6 versus 27 ± 6cm 2 ,P = 0.01. Early and late postoperative adverse events occurred at similar rates. Four patients from each group died of reasons unrelated to surgery. The mean follow-up was 66 ± 42 (5–155) months. In total, 184/229 (80%) patients were free of documented AF/atrial flutter/atrial tachycardia (AF/AFl/AT) off antiarrhythmic drugs (AA) and 189/229 (83%) on or off AA. The hazard ratio (HR) for paroxysmal versus nonparoxysmal AF patients regarding documented AF/AFl/AT was 0.8 (95% confidence interval [CI] 0.4–1.4; P = 0.40). For patients without versus with concomitant surgery, the corresponding HR was 0.4 (95% CI 0.2–0.8; P = 0.008). Of 197 patients (89%) responding to the questionnaire, 41 had sought care for symptoms of arrhythmia, 29 of whom had documented AF/AFl/AT, whereas another six had other arrhythmias. Conclusion: Cut-and-sew Cox maze III surgery provided long-lasting high efficacy, also in patients with nonparoxysmal AF of long duration and/or concomitant surgery, and was associated with low rates of subsequent adverse events. (PACE 2014; 37:147–156)

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

maze surgery
atrial fibrillation
pacemaker
mortality
concomitant surgery

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy