SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1938 1352
 

Sökning: L773:1938 1352 > Vibrotactile evalua...

Vibrotactile evaluation: Osseointegrated versus socket-suspended transfemoral prostheses

Häggström, Eva (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Hagberg, Kerstin, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Rydevik, Björn, 1947 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
visa fler...
Brånemark, Rickard, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
visa färre...
 (creator_code:org_t)
Journal of Rehabilitation Research & Development, 2013
2013
Engelska.
Ingår i: Journal of Rehabilitation Research and Development. - : Journal of Rehabilitation Research & Development. - 0748-7711 .- 1938-1352. ; 50:10, s. 1423-1434
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study investigated detection thresholds of vibrometric stimuli in patients with transfemoral amputation supplied with osseointegrated (OI) and socket-suspended prostheses. It included 17 patients tested preoperatively with socket-suspended prostheses and after 2 yr with OI prostheses and a control group (n = 17) using socket-suspended prostheses, evaluated once. Assessments on the prosthetic and intact feet were conducted at six frequencies (8, 16, 32, 64, 125, and 250 Hz). Furthermore, measurements were conducted to investigate how vibrometric signals are transmitted through a test prosthesis. The results showed that the OI group had improved ability to detect vibrations through the prosthesis at 125 Hz (p = 0.01) at follow-up compared with the preoperative measurement. Compared with the control group, the 01 group at follow-up had better ability to detect high frequency vibrations through the prosthesis (125 Hz, p = 0.02; 250 Hz, p = 0.03). The vibrometric signal transmitted through the test prosthesis was reduced at 8, 125, and 250 Hz but was amplified at 16, 32, and 64 Hz. Differences between the OI and the control groups were found in the highest frequencies in which the test prosthesis showed reduction of the vibrometric signal. The study provides insight into the mechanisms of vibration transmission between the exterior and bone-anchored as well as socket-suspended amputation prostheses.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

artificial limb
osseointegration
osseoperception
prosthesis
prosthetic foot
prosthetic knee
LOWER-LIMB AMPUTEES
TRANS-FEMORAL AMPUTEE
AMPUTATION PROSTHESES
DIABETIC NEUROPATHY
TITANIUM IMPLANTS
REHABILITATION
OSSEOPERCEPTION
VIBRATION
GAIT
STIMULATION

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Häggström, Eva
Hagberg, Kerstin ...
Rydevik, Björn, ...
Brånemark, Ricka ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Journal of Rehab ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy