Sökning: onr:"swepub:oai:gup.ub.gu.se/214221" >
Vectorcardiography ...
Vectorcardiography for Optimization of Stimulation Intervals in Cardiac Resynchronization Therapy.
-
van Deursen, Caroline J M (författare)
-
- Wecke, Liliane (författare)
- Karolinska Institutet
-
van Everdingen, Wouter M (författare)
-
visa fler...
-
- Ståhlberg, Marcus (författare)
- Karolinska Institutet
-
Janssen, Michel H G (författare)
-
- Braunschweig, Frieder (författare)
- Karolinska Institutet
-
- Bergfeldt, Lennart, 1950 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
-
Crijns, Harry J G M (författare)
-
Vernooy, Kevin (författare)
-
Prinzen, Frits W (författare)
-
visa färre...
-
(creator_code:org_t)
- 2015-03-06
- 2015
- Engelska.
-
Ingår i: Journal of cardiovascular translational research. - : Springer Science and Business Media LLC. - 1937-5395 .- 1937-5387. ; 8:2, s. 128-137
- Relaterad länk:
-
https://link.springe...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Current optimization of atrioventricular (AV) and interventricular (VV) intervals in cardiac resynchronization therapy (CRT) is time consuming and subject to noise. We aimed to prove the principle that the best hemodynamic effect of CRT is achieved by cancelation of opposing electrical forces, detectable from the QRS morphology in the 3D vectorcardiogram (VCG). Different degrees of left (LV) and right ventricular (RV) pre-excitation were induced, using variation in AV intervals during LV pacing in 20 patients with left bundle branch block (LBBB) and variation in VV intervals during biventricular pacing in 18 patients with complete AV block or atrial fibrillation. The smallest QRS vector area identified stimulation intervals with minimal systolic stretch (median difference [IQR] 20ms [-20, 20ms] and maximal hemodynamic response (10ms [-20, 40ms]). Reliability of VCG measurements was superior to hemodynamic measurements. This study proves the principle that VCG analysis may allow easy and reliable optimization of stimulation intervals in CRT patients.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
van Deursen, Car ...
-
Wecke, Liliane
-
van Everdingen, ...
-
Ståhlberg, Marcu ...
-
Janssen, Michel ...
-
Braunschweig, Fr ...
-
visa fler...
-
Bergfeldt, Lenna ...
-
Crijns, Harry J ...
-
Vernooy, Kevin
-
Prinzen, Frits W
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Kardiologi
- Artiklar i publikationen
-
Journal of cardi ...
- Av lärosätet
-
Göteborgs universitet
-
Karolinska Institutet