  • Trela, CBAM, Berlin, Germany (author)

Evaluation program of radar measurement with different polarisation : Sustainable Bridges Background document SB3.5

  • BookEnglish2007

Publisher, publication year, extent ...

  • 2007
  • 48 s.
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:ltu-75302
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-75302URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:rap swepub-publicationtype

Notes

  • EC Sixth Framework ProgramSustainable Bridges – Assessment for Future Traffic Demands and Longer LivesTIP3-CT-2003-001653
  • For the investigation of concrete structures, the main task is to detect and localise inhomogeneities such as untensioned reinforcement bars, tendon ducts, voids, pipes and other constructional elements and to estimate thickness of layered structures, based on the contrast in dielectric properties. Impulse radar has been applied very efficient to solve these problems. The method is based on the propagation of electromagnetic impulses having maximum frequencies between 500 MHz and 2.5 GHz for civil engineering applications. The waves are emitted by an antenna (transmitter), which is moved along the surface. The transmitting impulsesare reflected at interfaces of materials with different dielectric properties and detectedby a second antenna (receiver), also positioned on the surface. In most cases both antennas are close to each other, in the same housing (zero offset). Since radar cannot penetrate to metallic elements, rebars and tendon ducts are perfect reflectors.The following conclusions could be drawn from these results:· Detection of reinforcement bars being parallel and perpendicular to antenna movement depends strongly on the positioning of the antenna and the polarisation of the emitted electromagnetic waves. It is always easier to detect rebars which are crossed by the movement of the antenna. The highest intensity of reflection could be achieved if the polarisation is parallel to the rebars.· Detection of tendon ducts is possible, if the reinforcement grid above has not too small grid sizes (> 5 cm). In other cases, most part of the electromagnetic energy is reflected at the grid. To reduce the intensity of reflections from crossed rebars for a better detection of the tendon ducts, it is useful to select the polarisation perpendicular to the crossed rebars.· Detection of reinforcements and tendon ducts is possible with the 900 MHz as well as with the 1.5 GHz. With the 1.5 GHz antenna, a better resolution but less penetration depth could be achieved.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Niederleithinger, ErnstBAM, Berlin, Germany (author)
  • BAM, Berlin, Germany (creator_code:org_t)

Internet link

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Trela, C
Niederleithinger ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Infrastructure E ...
By the university
Luleå University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view