Mean Expected Error in Prediction of Total Body Water: A True Accuracy Comparison between Bioimpedance Spectroscopy and Single Frequency Regression Equations

Seoane, Fernando (författare)
Högskolan i Borås,KTH,Medicinska sensorer, signaler och system,Univ Boras, Fac Care Sci Work Life & Social Welfare, Sweden,Akademin för vård, arbetsliv och välfärd,KTH-School of Technology and Health
Abtahi, S. (författare)
Karolinska Institutet
Abtahi, Farhad, 1981- (författare)
Karolinska Institutet,KTH,Medicinska sensorer, signaler och system,Karolinska Inst, Dept Clin Sci Intervent & Technol, Sweden,KTH-School of Technology and Health
visa fler...
Ellegård, Lars, 1958 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,University of Gothenburg
Johannsson, Gudmundur, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,University of Gothenburg
Bosaeus, Ingvar, 1950 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition,University of Gothenburg
Ward, L. C. (författare)
University of Queensland
visa färre...
 (creator_code:org_t)
Hindawi Limited, 2015
2015
Engelska.
Ingår i: Biomed Research International. - : Hindawi Limited. - 2314-6133 .- 2314-6141. ; 2015:Article ID 656323
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun's prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

BIOELECTRICAL-IMPEDANCE ANALYSIS
FAT-FREE MASS
FLUID VOLUME
HEMODIALYSIS-PATIENTS
DILUTION METHODS
WHOLE-BODY
VALIDATION
MODEL
Biotechnology & Applied Microbiology
Medicine
Research & Experimental
URENBERG P
1995
BRITISH JOURNAL OF NUTRITION
V73
P349
Bioimpedance Spectroscopy
Människan i vården

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy