SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Guazzi Marco)
 

Sökning: WFRF:(Guazzi Marco) > Immediate, early (3...

Immediate, early (3 weeks) and conventional loading (4 months) of single implants: Preliminary data at 1 year after loading from a pragmatic multicenter randomised controlled trial

Grandi, T. (författare)
Guazzi, P. (författare)
Samarani, R. (författare)
visa fler...
Tohme, H. (författare)
Khoury, S. (författare)
Sbricoli, L. (författare)
Grandi, G. (författare)
Esposito, Marco, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
2015
2015
Engelska.
Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 8:2, s. 115-126
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To compare the clinical outcome of single implants which underwent immediate nonocclusal loading with implants subjected to early non-occlusal loading at 3 weeks, and implants conventionally loaded at 4 months. Materials and methods: One hundred and five patients in five private practices requiring a single implant-supported crown were randomised to immediate loading (35 patients), early loading (35 patients) and conventional loading (35 patients) groups. To be immediately or early loaded, implants had to be inserted with a torque superior to 45 Ncm. Immediately and early loaded implants received non-occluding temporary crows, whereas conventionally loaded implants were directly restored with definitive crowns. Temporary crowns were replaced by definitive ones after 4 months. Outcome measures were crown and implant failures, complications and pen-implant marginal bone level changes recorded by a blinded assessor. Results: Two patients dropped out from the immediate loading group up to 1-year post-loading. Two implants failed, one in the immediately loaded and one in the early loaded group (P = 0.601). One immediately loaded implant and two early loaded implants were affected by one complication each (P = 0.162). Mean pen-implant marginal bone loss after 1 year was -0.120 +/- 0.230 mm (95% Cl -0.35, 0.10) for immediate, -0.390 0.840 mm (95% Cl -1.23, 0.45) for early and -0.201 +/- 0.306 mm (95% Cl -0.51; 0.11) for conventionally loaded implants. There were no statistically significant differences for any of the outcome measures between the three loading strategies up to 1-year post-loading. Conclusions: No major clinical differences were observed with regard to implant survival, complications and marginal bone level changes when loading single implants immediately, early or conventionally.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

conventional loading
early loading
immediate loading
peri-implant
PARTIALLY EDENTULOUS PATIENTS
CONTROLLED CLINICAL-TRIAL
DENTAL
IMPLANTS
LOADED IMPLANTS
TOOTH IMPLANTS
AESTHETIC ZONE
FLAPLESS
OCCLUSAL
PROVISIONALIZATION
REPLACEMENT
Dentistry
Oral Surgery & Medicine

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy