SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Gu Irene Yu Hua 1953)
 

Sökning: WFRF:(Gu Irene Yu Hua 1953) > K-Optimal Gradient ...

K-Optimal Gradient Encoding Scheme for Fourth-Order Tensor-Based Diffusion Profile Imaging

Alipoor, Mohammad, 1983 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Gu, Irene Yu-Hua, 1953 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Mehnert, Andrew, 1967 (författare)
University of Western Australia
visa fler...
Maier, Stephan E, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology,University of Gothenburg
Starck, Göran (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
visa färre...
 (creator_code:org_t)
Hindawi Limited, 2015
2015
Engelska.
Ingår i: Biomed Research International. - : Hindawi Limited. - 2314-6133 .- 2314-6141.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The design of an optimal gradient encoding scheme (GES) is a fundamental problem in diffusion MRI. It is well studied for the case of second-order tensor imaging (Gaussian diffusion). However, it has not been investigated for the wide range of non-Gaussian diffusion models. The optimal GES is the one that minimizes the variance of the estimated parameters. Such a GES can be realized by minimizing the condition number of the design matrix (K-optimal design). In this paper, we propose a new approach to solve the K-optimal GES design problem for fourth-order tensor-based diffusion profile imaging. The problem is a nonconvex experiment design problem. Using convex relaxation, we reformulate it as a tractable semidefinite programming problem. Solving this problem leads to several theoretical properties of K-optimal design: (i) the odd moments of the K-optimal design must be zero; (ii) the even moments of the K-optimal design are proportional to the total number of measurements; (iii) the K-optimal design is not unique, in general; and (iv) the proposed method can be used to compute the K-optimal design for an arbitrary number of measurements. Our Monte Carlo simulations support the theoretical results and show that, in comparison with existing designs, the K-optimal design leads to the minimum signal deviation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

condition number
acquisition schemes
mri
directions
anisotropy
design
Biotechnology & Applied Microbiology
Research & Experimental Medicine
directions

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy