SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1094 687X OR L773:1558 4615 OR L773:9781424492718 OR L773:9781424492701
 

Sökning: L773:1094 687X OR L773:1558 4615 OR L773:9781424492718 OR L773:9781424492701 > (2015-2019) > Offline Accuracy: A...

Offline Accuracy: A Potentially Misleading Metric in Myoelectric Pattern Recognition for Prosthetic Control.

Ortiz Catalan, Max Jair, 1982 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Rouhani, Rouhani, 1988 (författare)
Brånemark, Rickard, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics,University of Gothenburg
visa fler...
Håkansson, Bo, 1953 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
ISBN 9781424492718
2015
2015
Engelska.
Ingår i: Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy, 15-19 August 2015. - 1557-170X. - 9781424492718 ; , s. 1140-1143
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Offline accuracy has been the preferred performance measure in myoelectric pattern recognition (MPR) for the prediction of motion volition. In this study, different metrics relating the fundamental binary prediction outcomes were analyzed. Our results indicate that global accuracy is biased by 1) the unbalanced number of possible true positive and negative outcomes, and 2) the almost perfect specificity and negative predicted value, which were consistently found across algorithms, topologies, and movements (individual and simultaneous). Therefore, class-specific accuracy is advisable instead. Additionally, we propose the use of precision (positive predictive value) and sensitivity (recall) as a complement to accuracy to better describe the discrimination capabilities of MPR algorithms, as these consider the effect of false predictions. However, all the studied offline metrics failed to predict real-time decoding, and therefore real-time testing continue to be necessary to truly evaluate the clinical usability of MPR.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)