Sökning: WFRF:(Gjertsson Peter 1961) >
IMPROVED PLANAR KID...
IMPROVED PLANAR KIDNEY ACTIVITY CONCENTRATION ESTIMATE BY THE POSTERIOR VIEW METHOD IN 177LU-DOTATATE TREATMENTS.
-
- Magnander, Tobias (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
- Svensson, Johanna (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för onkologi,Institute of Clinical Sciences, Department of Oncology
-
- Båth, Magnus, 1974 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
visa fler...
-
Gjertsson, Peter, 1961 (författare)
-
- Bernhardt, Peter, 1966 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
-
visa färre...
-
(creator_code:org_t)
- 2016-03-23
- 2016
- Engelska.
-
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4, s. 259-266
- Relaterad länk:
-
https://academic.oup...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The aims of this study were to determine how different background regions of interest (ROIs) around the kidney represent true background activity in over- and underlying tissues in(177)Lu-DOTA-octreatate ((177)Lu-DOTATATE) treatments and to determine the influence of the background positions on the kidney activity concentration estimates by the conjugate view (ConjV) and posterior view (PostV) methods. The analysis was performed in single-photon emission computed tomography (SPECT) images of 20 patients, acquired 24 h post injection of a(177)Lu-DOTATATE treatment, by a computer algorithm that created planar images from the SPECT data. The ratio between the activity concentration in the background and the true background varied from 0.36 to 2.08 [coefficient of variation (CV) = 25-181 %] and from 0.44 to 1.52 (CV = 16-70 %) for the right and left kidneys, respectively. The activity concentration estimate in the kidneys was most accurate with the PostV method using a background ROI surrounding the whole kidney, and this combination might be an alternative planar method for improved kidney dosimetry in the(177)Lu-DOTATATE treatments.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas