SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Johnsson Åse Allansdotter 1966)
 

Sökning: WFRF:(Johnsson Åse Allansdotter 1966) > Image Fusion of Rec...

Image Fusion of Reconstructed Digital Tomosynthesis Volumes From a Frontal and a Lateral Acquisition

Arvidsson, Jonathan (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
Söderman, Christina (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
Johnsson, Åse (Allansdotter), 1966 (författare)
Sahlgrenska universitetssjukhuset,Sahlgrenska University Hospital
visa fler...
Bernhardt, Peter, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
Starck, Göran (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
Kahl, Fredrik, 1972 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg
visa färre...
 (creator_code:org_t)
2015-12-18
2016
Engelska.
Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 169:1-4, s. 410-415
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Digital tomosynthesis (DTS) has been used in chest imaging as a low radiation dose alternative to computed tomography (CT). Traditional DTS shows limitations in the spatial resolution in the out-of-plane dimension. As a first indication of whether a dual-plane dual-view (DPDV) DTS data acquisition can yield a fair resolution in all three spatial dimensions, a manual registration between a frontal and a lateral image volume was performed. An anthropomorphic chest phantom was scanned frontally and laterally using a linear DTS acquisition, at 120 kVp. The reconstructed image volumes were resampled and manually co-registered. Expert radiologist delineations of the mediastinal soft tissues enabled calculation of similarity metrics in regard to delineations in a reference CT volume. The fused volume produced the highest total overlap, implying that the fused volume was a more isotropic 3D representation of the examined object than the traditional chest DTS volumes.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy