SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Håkansson Markus)
 

Sökning: WFRF:(Håkansson Markus) > Determination of th...

Determination of the two-dimensional detective quantum efficiency of a computed radiography system.

Båth, Magnus, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för särskilda specialiteter, Avdelningen för radiofysik,Institute of Selected Clinical Sciences, Department of Radiation Physics
Håkansson, Markus (författare)
Gothenburg University,Göteborgs universitet,Institutionen för särskilda specialiteter, Avdelningen för radiofysik,Institute of Selected Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för särskilda specialiteter, Avdelningen för radiofysik,Institute of Selected Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2003-11-20
2003
Engelska.
Ingår i: Medical physics. - : Wiley. - 0094-2405. ; 30:12, s. 3172-82
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Based on a recently described method for determining the two-dimensional presampling modulation transfer function (MTF), the aperture mask method, a method for determining the two-dimensional detective quantum efficiency (DQE) of a digital radiographic system was developed. The method was applied to a new computed radiography (CR) system and comparisons with one-dimensional determinations of the presampling MTF and the DQE were performed. The aperture mask method was shown to agree with the conventional tilted slit method for determining the presampling MTF along the axes. For the particular CR system studied, the mean of one-dimensional determinations of the DQE in orthogonal directions led to a representative measure of the average DQE behavior of the system up to the Nyquist frequency along the axes, but a deviation was observed above this frequency. In conclusion, the method developed for determining the two-dimensional DQE can be used to determine the imaging properties of a digital radiographic detector system over almost the entire frequency domain, the exception being the lowest frequencies (< or = 0.1 mm(-1)) at which the validity and the reliability of the method are low.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Algorithms
Equipment Failure Analysis
methods
Radiographic Image Enhancement
instrumentation
methods
Radiographic Image Interpretation
Computer-Assisted
methods
Reproducibility of Results
Sensitivity and Specificity
Signal Processing
Computer-Assisted

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Båth, Magnus, 19 ...
Håkansson, Marku ...
Månsson, Lars Gu ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Medical physics
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy