SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:gup.ub.gu.se/235266"
 

Search: id:"swepub:oai:gup.ub.gu.se/235266" > Investigation of th...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Svalkvist, AngelicaGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics (author)

Investigation of the dosimetry of chest tomosynthesis

  • Article/chapterEnglish2009

Publisher, publication year, extent ...

  • SPIE,2009

Numbers

  • LIBRIS-ID:oai:gup.ub.gu.se/235266
  • https://gup.ub.gu.se/publication/235266URI
  • https://doi.org/10.1117/12.810256DOI

Supplementary language notes

  • Language:English

Part of subdatabase

Classification

  • Subject category:vet swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Chest tomosynthesis has recently been introduced to healthcare as a low-dose alternative to CT or as a tool for improved diagnostics in chest radiography with only a modest increase in radiation dose to the patient. However, no detailed description of the dosimetry for this type of examination has been presented. The aim of this work was therefore to investigate the dosimetry of chest tomosynthesis. The chest tomosynthesis examination was assumed to be performed using a stationary detector and a vertically moving x-ray tube, exposing the patient from different angles. The Monte Carlo-based computer software PCXMC was used to determine the effective dose delivered to a standard-sized patient from various angles using different assumptions of the distribution of the effective dose over the different projections. The obtained relationships between input dose measures and effective dose for chest tomosynthesis for different angular intervals were then compared with the osteroanterior (PA) projection. The results indicate that the error is small when using the assumption that all effective dose in the case of chest tomosynthesis is delivered in PA projection for estimating the total effective dose for chest tomosynthesis for normally sized patients. This is especially true if the relationship between the kerma-area product (KAP) and effective dose is used. © 2009 SPIE.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Zachrisson, SaraGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xzacsa (author)
  • Månsson, Lars Gunnar,1951Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xmanla (author)
  • Båth, Magnus,1974Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics(Swepub:gu)xbatma (author)
  • Göteborgs universitetInstitutionen för kliniska vetenskaper, Avdelningen för radiofysik (creator_code:org_t)

Related titles

  • In:Progress in Biomedical Optics and Imaging - Proceedings of SPIE: SPIE72581605-7422

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view