SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Passarelli C)
 

Sökning: WFRF:(Passarelli C) > Peptide Fragmentati...

Peptide Fragmentation and Surface Structural Analysis by Means of ToF-SIMS Using Large Cluster Ion Sources

Yokoyama, Y. (författare)
Aoyagi, S. (författare)
Fujii, M. (författare)
visa fler...
Matsuo, J. (författare)
Fletcher, John S. (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology,University of Gothenburg
Lockyer, N. P. (författare)
Vickerman, J. C. (författare)
Passarelli, Melissa, 1983 (författare)
Havelund, R. (författare)
Seah, M. P. (författare)
visa färre...
 (creator_code:org_t)
2016-03-09
2016
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 88:7, s. 3592-3597
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Peptide or protein structural analysis is crucial for the evaluation of biochips and biodevices, therefore an analytical technique with the ability to detect and identify protein and peptide species directly from surfaces with high lateral resolution is required. In this report, the efficacy of ToF-SIMS to analyze and identify proteins directly from surfaces is evaluated. Although the physics governing the SIMS bombardment process precludes the ability for researchers to detect intact protein or larger peptides of greater than a few thousand mass unit directly, it is possible to obtain information on the partial structures of peptides or proteins using low energy per atom argon duster ion beams. Large cluster ion beams, such as Ar dusters and C-60 ion beams, produce spectra similar to those generated by tandem MS. The SIMS bombardment process also produces peptide fragment ions not detected by conventional MS/MS techniques. In order to clarify appropriate measurement conditions for peptide structural analysis, peptide fragmentation dependency on the energy of a primary ion beam and ToF-SIMS specific fragment ions are evaluated. It was found that the energy range approximately 6 <= E/n <= 10 eV/atom is most effective for peptide analysis based on peptide fragments and [M + H] ions. We also observed the cleaving of side chain moieties at extremely low-energy E/n <= 4 eV/atom.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

mass-spectrometry
universal equation
ar cluster
argon
beams
energy
yields
size
Chemistry
mass-spectrometry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy