SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/239596"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/239596" > Immediate loading o...

Immediate loading of two (fixed-on-2) versus three (fixed-on-3) implants placed flapless supporting cross-arch fixed prostheses: One-year results from a randomised controlled trial

Cannizzaro, G. (författare)
Loi, I. (författare)
Viola, P. (författare)
visa fler...
Ferri, V. (författare)
Leone, M. (författare)
Trullenque-Eriksson, A. (författare)
Esposito, Marco, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
2016
2016
Engelska.
Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 9:2, s. 143-153
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To evaluate the outcome of two (fixed-on-2 = FO2) versus three (fixed-on-3 = FO3) implants placed flapless in fully edentulous jaws and immediately restored with metal-resin screw-retained crossarch prostheses. Materials and methods: Forty edentulous or to be rendered edentulous patients (20 in the maxilla and 20 in the mandible) were randomised to the FO2 group (20 patients: 10 in the maxilla and 10 in the mandible) and to the FO3 group (20 patients: 10 in the maxilla and 10 in the mandible) according to a parallel group design. To be immediately loaded, implants had to be inserted with a minimum torque of 60 Ncm. Outcome measures were prosthesis and implant failures, complications and peri-implant marginal bone level changes evaluated up to 1-year post-loading. Results: Flaps were raised in four patients and two prostheses were loaded early at 8 weeks in the FO2 group. One year after loading no dropout or implant failure occurred, however one FO2 maxillary prosthesis had to be remade because of repeated screw-loosening (risk difference = 0.05; 95% CI: -0.05 to 0.15; Fisher's exact test P = 1.000). Three FO2 patients were affected by complications versus five FO3 patients (risk difference = -0.1; 95% CI: -0.35 to 0.15; Fisher's exact test; P = 0.695). There were no statistically significant differences for prosthetic failures and complications between groups. There were no statistically significant differences for marginal peri-implant bone levels between the two groups (estimate of the difference = 0.031 mm; 95% Cl: -0.22 to 0.28; P (ancova) = 0.803), with both groups losing marginal bone in a statistically significant way (0.27 mm for FO2 patients and 0.24 mm for FO3 patients). Conclusions: These preliminary results suggest that immediately loaded cross-arch prostheses can be supported by only two or three dental implants at least up to 1-year post-loading. Longer follow-ups are needed to properly evaluate both these therapeutic options.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

All-on-2
dental implants
flapless
immediate loading
randomised controlled trial
retained mandibular overdentures
controlled clinical-trial
4
endosseous implants
dental implants
follow-up
surgery
system
torque
Dentistry
Oral Surgery & Medicine

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy