SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Yhlen B.)
 

Sökning: WFRF:(Yhlen B.) > Method for Bacteria...

Method for Bacterial Growth and Ammonia Production and Effect of Inhibitory Substances in Disposable Absorbent Hygiene Products

Forsgren-Brusk, U. (författare)
Yhlen, B. (författare)
Blomqvist, M. (författare)
visa fler...
Larsson, Peter (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för infektionssjukdomar,Institute of Biomedicine, Department of Infectious Medicine
visa färre...
 (creator_code:org_t)
Ovid Technologies (Wolters Kluwer Health), 2017
2017
Engelska.
Ingår i: Journal of Wound Ostomy and Continence Nursing. - : Ovid Technologies (Wolters Kluwer Health). - 1071-5754. ; 44:1, s. 78-83
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: The purpose of this study was to evaluate a pragmatic laboratory method to provide a technique for developing incontinence products better able to reduce malodor when used in the clinical setting. METHODS: Bacterial growth and bacterially formed ammonia in disposable absorbent incontinence products was measured by adding synthetic urine inoculated with bacteria to test samples cut from the crotch area of the product. The inhibitory effect's of low pH (4.5 and 4.9) and 3 antimicrobial substanceschlorhexidine, polyhexamethylene biguanide (PHMB), and thymolat 2 concentrations each, were studied. RESULTS: From the initial inocula of 3.3 log colony-forming units per milliliter (cfu/mL) at baseline, the bacterial growth of the references increased to 5.0 to 6.0 log cfu/mL at 6 hours for Escherichia coli, Proteus mirabilis, and Enterococcus faecalis. At 12 hours there was a further increase to 7.0 to 8.9 log cfu/mL. Adjusting the pH of the superabsorbent in the incontinence product from 6.0 to pH 4.5 and pH 4.9 significantly (P < .05) inhibited the bacterial growth rates, in most cases, both at 6 and 12 hours. The effect was most pronounced at pH 4.5. Chlorhexidine had significant (P < .05) inhibitory effect on E. coli and E. faecalis, and at 12 hours also on P. mirabilis. For PHMB and thymol the results varied. At 6 hours, the ammonia concentration in the references (pH 6.0) was 200 to 300 ppm and it was 1500 to 1600 ppm at 8 hours. At pH 4.5, no or little ammonia production was measured at 6 and 8 hours. At pH 4.9, there was a significant reduction (P < .01). Chlorhexidine and PHMB exerted a significant (P < .01 or P < .001) inhibitory effect on ammonia production at both concentrations and at 6 and 8 hours. Thymol 0.003% and 0.03% showed inhibitory effect at both 6 hours (P < .01 or P < .001) and at 8 hours (P < .05 or P < .001). CONCLUSION: The method described in this study can be used to compare the ability of various disposable absorbent products to inhibit bacterial growth and ammonia production. This technique, we describe, provides a pragmatic method for assessing the odor-inhibiting capacity of specific incontinence products.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

Absorbent hygiene products
Ammonia production
Bacterial growth
Incontinence
Odor control
urinary-incontinence
Nursing

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Forsgren-Brusk, ...
Yhlen, B.
Blomqvist, M.
Larsson, Peter
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Journal of Wound ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy