Evaluation of a method for isocapnic hyperventilation: a clinical pilot trial.
-
- Hallén, Katarina (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
-
- Jildenstål, Pether (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
-
- Stenqvist, Ola, 1944 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
-
visa fler...
-
- Ricksten, Sven-Erik, 1953 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
-
- Lindgren, Sophie, 1971 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care
-
visa färre...
-
(creator_code:org_t)
- 2017-10-16
- 2018
- Engelska.
-
Ingår i: Acta anaesthesiologica Scandinavica. - : Wiley. - 1399-6576 .- 0001-5172. ; 62:2, s. 186-195
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Isocapnic hyperventilation (IHV) is a method that shortens time to extubation after inhalation anaesthesia using hyperventilation (HV) without lowering airway CO2 . In a clinical trial on patients undergoing long-duration sevoflurane anaesthesia for major ear-nose-throat (ENT) surgery, we evaluated the utility of a technique for CO2 delivery (DCO2 ) to the inspiratory limb of a closed breathing circuit, during HV, to achieve isocapnia.Fifteen adult ASA 1-3 patients were included. After end of surgery, mechanical HV was started by doubling baseline minute ventilation. Simultaneously, CO2 was delivered and dosed using a nomogram developed in a previous experimental study. Time to extubation and eye opening was recorded. Inspired (FICO2 ) and expired (FETCO2 ) CO2 and arterial CO2 levels were monitored during IHV. Cognition was tested pre-operatively and at 20, 40 and 60 min after surgery.A DCO2 of 285 ± 45 ml/min provided stable isocapnia during HV (13.5 ± 4.1 l/min). The corresponding FICO2 level was 3.0 ± 0.3%. Time from turning off the vaporizer (1.3 ± 0.1 MACage) to extubation (0.2 ± 0.1 MACage) was 11.3 ± 1.8 min after 342 ± 131 min of anaesthesia. PaCO2 and FETCO2 remained at normal levels during and after IHV. In 85% of the patients, post-operative cognition returned to pre-operative values within 60 min.In this cohort of patients, a DCO2 nomogram for IHV was validated. The patients were safely extubated shortly after discontinuing long-term sevoflurane anaesthesia. Perioperatively, there were no adverse effects on arterial blood gases or post-operative cognition. This technique for IHV can potentially be used to decrease emergence time from inhalation anaesthesia.