Influence of patient position and other inherent factors on image quality in two different cone beam computed tomography (CBCT) devices

Lindfors, Ninita (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Lund, Henrik, 1975 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Johansson, H. (author)
show more...
Ekestubbe, Annika, 1953 (author)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
show less...
 (creator_code:org_t)
Elsevier BV, 2017
2017
English.
In: European Journal of Radiology Open. - : Elsevier BV. - 2352-0477. ; 4, s. 132-137
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objectives The aim of this in vitro study was to evaluate how a deviation from the horizontal plane, affects the image quality in two different CBCT-devices. Methods A phantom head SK150 (RANDO, The Phantom Laboratory, Salem, NY, USA) was examined in two CBCT-units: Accuitomo 80 and Veraviewepocs 3D R100 (J. Morita Mfg. Corp. Kyoto, Japan). The phantom head was placed with the hard palate parallel to the horizontal plane and tilted 20 ° backwards. Exposures were performed with different field of views (FOVs), voxel sizes, slice thicknesses and exposure settings. Effective dose was calculated using PCXMC 2.0 (STUK, Helsinki, Finland). Image quality was assessed using contrast-to-noise-ratio (CNR). Region of interest (ROI) was set at three different levels of the mandibular bone and soft tissue, uni- and bilaterally in small and large FOVs, respectively. CNR values were calculated by CT-value and standard deviation for each ROI. Factor analysis was used to analyze the material. Results Tilting the phantom head backwards rendered significantly higher mean CNR values regardless of FOV. The effective dose was lower in small than in large FOVs and varied to a larger extent between CBCT-devices in large FOVs. Conclusions Head position can affect the image quality. Tilting the head backward improved image quality in the mandibular region. However, if influenced by other variables e.g. motion artifacts in a clinical situation, remains to be further investigated. Advances in knowledge Image quality assessed using CNR values to investigate the influence of different patient positions and FOVs. © 2017 The Author(s)

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

CBCT
FOV
Image quality
Patient position
Radiation dose

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Lindfors, Ninita
Lund, Henrik, 19 ...
Johansson, H.
Ekestubbe, Annik ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
European Journal ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view