Sökning: L773:0090 6964 OR L773:1573 9686
> (2015-2019) >
Biomechanical Chara...
Biomechanical Characterisation of Bone-anchored Implant Systems for Amputation Limb Prostheses: A Systematic Review
-
- Thesleff, Alexander, 1986 (författare)
- Integrum AB,Chalmers tekniska högskola,Chalmers University of Technology
-
- Brånemark, Rickard, 1960 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences,University of California,University of Gothenburg
-
- Håkansson, Bo, 1953 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
visa fler...
-
- Ortiz Catalan, Max Jair, 1982 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology,Integrum AB
-
visa färre...
-
(creator_code:org_t)
- 2018-01-11
- 2018
- Engelska.
-
Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 0090-6964 .- 1573-9686. ; 46:3, s. 377-391
- Relaterad länk:
-
https://link.springe...
-
visa fler...
-
https://research.cha... (primary) (free)
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- Bone-anchored limb prostheses allow for the direct transfer of external loads from the prosthesis to the skeleton, eliminating the need for a socket and the associated problems of poor fit, discomfort, and limited range of movement. A percutaneous implant system for direct skeletal attachment of an external limb must provide a long-term, mechanically stable interface to the bone, along with an infection barrier to the external environment. In addition, the mechanical integrity of the implant system and bone must be preserved despite constant stresses induced by the limb prosthesis. Three different percutaneous implant systems for direct skeletal attachment of external limb prostheses are currently clinically available and a few others are under investigation in human subjects. These systems employ different strategies and have undergone design changes with a view to fulfilling the aforementioned requirements. This review summarises such strategies and design changes, providing an overview of the biomechanical characteristics of current percutaneous implant systems for direct skeletal attachment of amputation limb prostheses.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Inbäddad systemteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Embedded Systems (hsv//eng)
- NATURVETENSKAP -- Data- och informationsvetenskap -- Datavetenskap (hsv//swe)
- NATURAL SCIENCES -- Computer and Information Sciences -- Computer Sciences (hsv//eng)
Nyckelord
- Bone-anchored prostheses
- Osseointegration
- Direct skeletal attachment
- percutaneous osseointegrated prostheses
- suspended transfemoral
- prostheses
- direct skeletal attachment
- quality-of-life
- radiographic
- evaluation
- socket prostheses
- titanium implants
- amputees
- rehabilitation
- vibrotactile
- Engineering
- Osseointegration
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas