SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1475 0961
 

Sökning: L773:1475 0961 > (2015-2019) > Comparison between ...

  • Hjelmgren, OlaGothenburg University,Göteborgs universitet,Wallenberglaboratoriet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Wallenberg Laboratory,Institute of Medicine, Department of Molecular and Clinical Medicine,Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Mol & Clin Med,Wallenberg Lab, Gothenburg, Sweden;Sahlgrens Univ Hosp, Dept Clin Physiol, Gothenburg, Sweden (författare)

Comparison between magnetic resonance imaging and B-mode ultrasound in detecting and estimating the extent of human carotid atherosclerosis

  • Artikel/kapitelEngelska2018

Förlag, utgivningsår, omfång ...

  • 2017-03-02
  • Wiley,2018

Nummerbeteckningar

  • LIBRIS-ID:oai:gup.ub.gu.se/266495
  • https://gup.ub.gu.se/publication/266495URI
  • https://doi.org/10.1111/cpf.12415DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-386317URI

Kompletterande språkuppgifter

  • Språk:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Background In MRI studies of carotid plaques, ultrasound is used to find plaques, which are later imaged using MRI. The performance in plaque detection has not been compared between the modalities. The aim of the current study was to compare the performance of MRI and ultrasound in detecting carotid artery plaques and measuring extent of atherosclerosis. Methods Subjects with at least one plaque (height >= 2.5mm) on ultrasound were imaged using MRI. The number of plaques and their height was measured in both modalities; plaque area and volume were analysed on ultrasound and MRI, respectively. Results Thirty-eight subjects were included. MRI detected plaques in 95% of carotid arteries with a plaque height of 2.5 mm on ultrasound and in all carotid arteries with a plaque exceeding >= 2.5 mm. MRI detected 53% of the plaques with a height below 2.5mm. The plaque height measured with both techniques correlated significantly, 0.59, P<0.0001. Ultrasound-derived plaque height and plaque area correlated similarly to MRI-derived plaque volume, r = 0.52; P<0.0001 and r = 0.47; P = 0.001, respectively. Conclusions We conclude that MRI has a similar sensitivity to ultrasound in finding carotid artery plaques that are 2.5 mm or higher. In smaller plaques, MRI detects fewer plaques. Multiple carotid plaques seen on ultrasound most often are a misinterpretation of the anatomy and correspond to a single plaque. Plaque height on ultrasound is comparable to plaque height on MRI and correlates fairly well with plaque volume on MRI making it an interesting proxy for plaque burden.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Schmidt, Caroline,1966Gothenburg University,Göteborgs universitet,Wallenberglaboratoriet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Wallenberg Laboratory,Institute of Medicine, Department of Molecular and Clinical Medicine,Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Mol & Clin Med,Wallenberg Lab, Gothenburg, Sweden(Swepub:gu)xschca (författare)
  • Johansson, LarsUppsala universitet,Radiologi(Swepub:uu)larsjoha (författare)
  • Bergström, Göran,1964Gothenburg University,Göteborgs universitet,Wallenberglaboratoriet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Wallenberg Laboratory,Institute of Medicine, Department of Molecular and Clinical Medicine,Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Mol & Clin Med,Wallenberg Lab, Gothenburg, Sweden;Sahlgrens Univ Hosp, Dept Clin Physiol, Gothenburg, Sweden(Swepub:gu)xbgort (författare)
  • Göteborgs universitetWallenberglaboratoriet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Clinical Physiology and Functional Imaging: Wiley38:2, s. 296-3031475-09611475-097X