SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1879 1220 OR L773:0960 0760
 

Sökning: L773:1879 1220 OR L773:0960 0760 > High-sensitivity qu...

High-sensitivity quantification of serum androstenedione, testosterone, dihydrotestosterone, estrone and estradiol by gas chromatography-tandem mass spectrometry with sex- and puberty-specific reference intervals.

Ankarberg-Lindgren, Carina, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
Dahlgren, Jovanna, 1964 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
Andersson, Mats X., 1977 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biologi och miljövetenskap,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Department of Biological and Environmental Sciences,Institute of Clinical Sciences, Department of Pediatrics
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: The Journal of steroid biochemistry and molecular biology. - : Elsevier BV. - 1879-1220 .- 0960-0760. ; 183, s. 116-124
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Androgen and estrogen determinations serve as important diagnostic markers in a variety of clinical conditions. However, one challenge is to enhance assay sensitivity for determination in the lowest range, such as in prepubertal children. We here present a recently developed gas chromatography-tandem mass spectrometry (GC-MS/MS) method for determination of androstenedione (A4), dihydrotestosterone (DHT), testosterone (T), estrone (E1), and estradiol (E2) in children, which we have compared with the sensitive radioimmunoassays; E2 extraction-RIA and T-RIA.Steroids were extracted in ethyl acetate n-hexane solution from serum spiked with isotopically labeled internal standard and derivatized sequentially with pentafluorobenzyl bromide, pentafluorobenzyl hydroxylamine and pentafluoropropionic acid anhydride and analyzed by GC-MS/MS using a triple quadrupole mass spectrometer operated in negative chemical ionization mode. Leftover routine samples (n=414) were used to evaluate the concordance between GC-MS/MS and RIAs and the validity of GC-MS/MS for pediatrics; of these samples, 101 were from seemingly healthy children. Pubertal stage was recorded for reference interval evaluation.Lower limit of detection for A4, T, DHT, E1, and E2 were 0.1nmol/L, 0.1nmol/L, 27pmol/L, 9pmol/L, and 2pmol/L, respectively. Good agreement was found between GC-MS/MS and T-RIA (r=0.98) as well as between GC-MS/MS and E2 extraction-RIA (r=0.98, for E2 concentrations above 14pmol/L). In boys, T and DHT increased significantly from prepuberty throughout pubertal development, and in girls the same increase was observed for E1 and E2. The greatest increase in A4 for both genders, as well as E1 and E2 in boys and T and DHT in girls, occurred in mid to late puberty.We report the development of a GC-MS/MS method sensitive enough to accurately determine serum levels of androgens and estrogens in children.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ankarberg-Lindgr ...
Dahlgren, Jovann ...
Andersson, Mats ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Pediatrik
Artiklar i publikationen
The Journal of s ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy