Semi-automatic analysis of standard uptake values in serial PET/CT studies in patients with lung cancer and lymphoma

Ly, John (författare)
Garpered, Sabine (författare)
Höglund, Peter (författare)
visa fler...
Jönsson, Eskil (författare)
Valind, Sven (författare)
Edenbrandt, Lars, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Wollmer, Per (författare)
visa färre...
 (creator_code:org_t)
2012-04-02
2012
Engelska.
Ingår i: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 12
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Changes in maximum standardised uptake values (SUVmax) between serial PET/CT studies are used to determine disease progression or regression in oncologic patients. To measure these changes manually can be time consuming in a clinical routine. A semi-automatic method for calculation of SUVmaxin serial PET/CT studies was developed and compared to a conventional manual method. The semi-automatic method first aligns the serial PET/CT studies based on the CT images. Thereafter, the reader selects an abnormal lesion in one of the PET studies. After this manual step, the program automatically detects the corresponding lesion in the other PET study, segments the two lesions and calculates the SUVmaxin both studies as well as the difference between the SUVmaxvalues. The results of the semi-automatic analysis were compared to that of a manual SUVmaxanalysis using a Philips PET/CT workstation. Three readers did the SUVmaxreadings in both methods. Sixteen patients with lung cancer or lymphoma who had undergone two PET/CT studies were included. There were a total of 26 lesions.Results: Linear regression analysis of changes in SUVmaxshow that intercepts and slopes are close to the line of identity for all readers (reader 1: intercept = 1.02, R2= 0.96; reader 2: intercept = 0.97, R2= 0.98; reader 3: intercept = 0.99, R2= 0.98). Manual and semi-automatic method agreed in all cases whether SUVmaxhad increased or decreased between the serial studies. The average time to measure SUVmaxchanges in two serial PET/CT examinations was four to five times longer for the manual method compared to the semi-automatic method for all readers (reader 1: 53.7 vs. 10.5 s; reader 2: 27.3 vs. 6.9 s; reader 3: 47.5 vs. 9.5 s; p < 0.001 for all).Conclusions: Good agreement was shown in assessment of SUVmaxchanges between manual and semi-automatic method. The semi-automatic analysis was four to five times faster to perform than the manual analysis. These findings show the feasibility of using semi-automatic methods for calculation of SUVmaxin clinical routine and encourage further development of programs using this type of methods. © 2012 Ly et al; licensee BioMed Central Ltd.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

Image analysis
Quantification
Radionuclide imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)