SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2352 8729
 

Sökning: L773:2352 8729 > (2018) > Interlaboratory val...

Interlaboratory validation of cerebrospinal fluid α-synuclein quantification in the diagnosis of sporadic Creutzfeldt-Jakob disease

Kruse, N. (författare)
Heslegrave, A. (författare)
Gupta, V. (författare)
visa fler...
Foiani, M. (författare)
Villar-Piqué, A. (författare)
Schmitz, M. (författare)
Lehmann, S. (författare)
Teunissen, C. (författare)
Blennow, Kaj, 1958 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi,Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry
Zetterberg, Henrik, 1973 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi,Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry
Mollenhauer, B. (författare)
Zerr, I. (författare)
Llorens, F. (författare)
visa färre...
 (creator_code:org_t)
2018-07-06
2018
Engelska.
Ingår i: Alzheimer's and Dementia: Diagnosis, Assessment and Disease Monitoring. - : Wiley. - 2352-8729. ; 10, s. 461-470
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction Cerebrospinal fluid α-synuclein level is increased in sporadic Creutzfeldt-Jakob disease cases. However, the clinical value of this biomarker remains to be established. In this study, we have addressed the clinical validation parameters and the interlaboratory reproducibility by using an electrochemiluminescent assay. Methods Cerebrospinal fluid α-synuclein was quantified in a total of 188 sporadic Creutzfeldt-Jakob disease and non–Creutzfeldt-Jakob-disease cases to determine sensitivity and specificity values and lot-to-lot variability. Two round robin tests with 70 additional cases were performed in six independent laboratories. Results A sensitivity of 93% and a specificity of 96% were achieved in discriminating sporadic Creutzfeldt-Jakob disease. No differences were detected between lots. The mean interlaboratory coefficient of variation was 23%, and the intralaboratory coefficient of variations ranged 2.70%–11.39%. Overall, 97% of samples were correctly diagnosed. Discussion The herein validated α-synuclein assay is robust, accurate, and reproducible in identifying Creutzfeldt-Jakob disease cases. Thus, it is ready for implementation in the clinical practice to support the diagnosis of Creutzfeldt-Jakob disease.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy