Noninvasive in vivo Assessment of the Re-endothelialization Process Using Ultrasound Biomicroscopy in the Rat Carotid Artery Balloon Injury Model.

Röhl, Samuel (författare)
Karolinska Institutet
Eriksson, Linnea (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Saxelin, Robert (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
visa fler...
Lengquist, Mariette (författare)
Karolinska Institutet
Östenson, Claes-Göran (författare)
Karolinska Institutet
Hedin, Ulf (författare)
Karolinska Institutet
Caidahl, Kenneth, 1949 (författare)
Karolinska Institutet,Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Razuvaev, Anton (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2018-11-13
2019
Engelska.
Ingår i: Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. - : Wiley. - 1550-9613. ; 38:7, s. 1723-1731
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Ultrasound biomicroscopy (UBM), or ultra high-frequency ultrasound, is a technique used to assess the anatomy of small research animals. In this study, UBM was used to assess differences in intimal hyperplasia thickness as a surrogate measurement of the re-endothelialization process after carotid artery balloon injury in rats.Ultrasound biomicroscopic data from 3 different experiments and rat strains (Sprague Dawley, Wistar, and diabetic Goto-Kakizaki) were analyzed. All animals were subjected to carotid artery balloon injury and examined with UBM (30-70 MHz) 2 and 4 weeks after injury. Re-endothelialization on UBM was defined as the length from the carotid bifurcation to the most distal visible edge of the intimal hyperplasia. En face staining with Evans blue dye was performed at euthanasia 4 weeks after injury, followed by tissue harvesting for histochemical and immunohistochemical evaluations.A significant correlation (Spearman r=0.63; P<.0001) was identified when comparing all measurements of re-endothelialization obtained from UBM and en face staining. The findings revealed a similar pattern for all rat strains: Sprague Dawley (Spearman r=0.70; P<.0001), Wistar (Spearman r=0.36; P<.081), and Goto-Kakizaki (Spearman r=0.70; P<.05). A Bland-Altman test showed agreement between en face staining and UBM. Immunohistochemical staining confirmed the presence of the endothelium in the areas detected as re-endothelialized by the UBM assessment.Ultrasound biomicroscopy can be used for repeated in vivo assessment of re-endothelialization after carotid artery balloon injury in rats.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

arterial injury; re-endothelialization; ultrasound biomicroscopy; vascular ultrasound

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy