SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0300 9742 OR L773:1502 7732
 

Sökning: L773:0300 9742 OR L773:1502 7732 > Responsiveness of d...

Responsiveness of different dynamic contrast-enhanced magnetic resonance imaging approaches: a post-hoc analysis of a randomized controlled trial of certolizumab pegol in rheumatoid arthritis

Axelsen, M. B. (författare)
Boesen, M. (författare)
Bliddal, H. (författare)
visa fler...
Jacobsson, Lennart T. H., 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för reumatologi och inflammationsforskning,Institute of Medicine, Department of Rheumatology and Inflammation Research
Hansen, M. S. (författare)
Ostergaard, M. (författare)
visa färre...
 (creator_code:org_t)
2019-09-16
2020
Engelska.
Ingår i: Scandinavian Journal of Rheumatology. - : Informa UK Limited. - 0300-9742 .- 1502-7732. ; 49:2, s. 105-111
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: The aim was to explore dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as an early marker of therapeutic response in patients with rheumatoid arthritis (RA) starting treatment with certolizumab pegol (CZP). Method: In 40 RA patients initiating CZP (27 patients) or 2 weeks of placebo (PCB) followed by CZP (13 patients), DCE-MRI of the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints was performed at weeks 0, 1, 2, 4, 8, and 16. Using semi-automated software, three methods for drawing volume regions of interest (ROIs) in MCP2-5 and PIP2-5 were applied: 'Standard' (slices: all; joints: MCP2-5 together and PIP2-5 together), 'Detailed' (slices: slices with high-quality visualization; joints: as Standard), and 'Single-joint' (slices: as Detailed; joints: each joint separately). The number of enhancing voxels (Nvoxel), initial rate of enhancement (IRE), and maximum enhancement (ME) were extracted and analysed for each method. Results: Nvoxel in MCP2-5, and IRE and ME in PIP2-5 decreased statistically significantly (Wilcoxon rank-sum test, p < 0.02-0.03) after 16 weeks of treatment for the Standard method. Nvoxel and ME decreased significantly more in the CZP group than in the PCB group after 1 week of treatment, but not at later time-points. There were no significant changes for DCE-MRI parameters for the Detailed and Single-joint methods. Conclusions: Certain DCE-MRI parameters detected decreased inflammation during CZP treatment in RA patients. Using specific criteria for ROIs, as in the Detailed and Single-joint methods, decreased the statistical power and could not show any changes over time.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reumatologi och inflammation (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Rheumatology and Autoimmunity (hsv//eng)

Nyckelord

bone-marrow edema
gadolinium-dtpa
mri assessment
synovitis
wrist
inflammation
progression
scores
ra
Rheumatology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy