SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lannering Katarina)
 

Sökning: WFRF:(Lannering Katarina) > Low false-positive ...

Low false-positive rate of perfusion index as a screening tool for neonatal aortic coarctation

Lannering, Katarina (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
Elfvin, Anders, 1971 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
Mellander, Mats, 1947 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
 (creator_code:org_t)
2020-12-02
2021
Engelska.
Ingår i: Acta Paediatrica, International Journal of Paediatrics. - : Wiley. - 0803-5253 .- 1651-2227. ; 110:6, s. 1788-1794
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • © 2020 The Authors. Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica Aim: Adding perfusion index (PI) to pulse oximetry screening (POS) may increase neonatal detection of CoA (aortic coarctation). A cut-off <0.7% has been suggested but is associated with a high rate of false positives. We aimed to evaluate the specificity of PI when using repeated instead of single measurements. Methods: A pilot study was conducted in 50 neonates. PI was recorded in right hand and a foot by pulse oximeter. If PI was <0.7%, the measurement was immediately repeated up to 3 times. If all three measurements were <0.7% in hand and/or foot the screen was positive and echocardiography was performed. There were 3/50 false-positive screens. The protocol was therefore modified requiring 30min intervals between measurements. Results: An additional 463 neonates were included using the modified protocol at a median age of 18h. There were no false positives. The only neonate with CoA had a negative screen (PI hand 1.2% and foot 0.8%). The measurement required on average an extra 3min and 30s compared with POS only. Conclusion: The false-positive rate of PI was reduced by using repeated PI measurements. The sensitivity for CoA using this protocol should be evaluated in large-scale prospective studies.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Nyckelord

aortic coarctation
perfusion index
screening

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lannering, Katar ...
Elfvin, Anders, ...
Mellander, Mats, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Pediatrik
Artiklar i publikationen
Acta Paediatrica ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy