SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sorensson P)
 

Sökning: WFRF:(Sorensson P) > (2020-2023) > Comprehensive Cardi...

  • Ramos, J. G. (författare)

Comprehensive Cardiovascular Magnetic Resonance Diastolic Dysfunction Grading Shows Very Good Agreement Compared With Echocardiography

  • Artikel/kapitelEngelska2020

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2020

Nummerbeteckningar

  • LIBRIS-ID:oai:gup.ub.gu.se/301071
  • https://gup.ub.gu.se/publication/301071URI
  • https://doi.org/10.1016/j.jcmg.2020.06.027DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:145522538URI

Kompletterande språkuppgifter

  • Språk:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • OBJECTIVES The aims of this study were to develop a comprehensive cardiovascular magnetic resonance (CMR) approach to diastolic dysfunction (DD) grading and to evaluate the accuracy of CMR in the diagnosis of DD compared with echocardiography. BACKGROUND Left ventricular DD is routinely assessed using echocardiography. METHODS Consecutive clinically referred patients (n = 46; median age 59 years; interquartile range: 46 to 68 years; 33% women) underwent both conventional echocardiography and CMR. CMR diastolic transmitral velocities (E and A) and myocardial tissue velocity (e0) were measured during breath-hold using a validated high-temporal resolution radial sector-wise golden-angle velocity-encoded sequence. CMR pulmonary artery pressure was estimated from 4-dimensional flow analysis of blood flow vortex duration in the pulmonary artery. CMR left atrial volume was measured using the biplane long-axis area-length method. Both CMR and echocardiographic data were used to perform blinded grading of DD according to the 2016 joint American and European recommendations. RESULTS Grading of DD by CMR agreed with that by echocardiography in 43 of 46 cases (93%), of which 9% were normal, 2% indeterminate, 63% grade 1 DD, 4% grade 2 DD, and 15% grade 3 DD. There was a very good categorical agreement, with a weighted Cohen kappa coefficient of 0.857 (95% confidence interval: 0.73 to 1.00; p < 0.001). CONCLUSIONS A comprehensive CMR protocol for grading DD encompassing diastolic blood and myocardial velocities, estimated pulmonary artery pressure, and left atrial volume showed very good agreement with echocardiography. (C) 2020 by the American College of Cardiology Foundation.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Fyrdahl, A.Karolinska Institutet (författare)
  • Wieslander, B.Karolinska Institutet (författare)
  • Thalen, S.Karolinska Institutet (författare)
  • Reiter, G. (författare)
  • Reiter, U. (författare)
  • Jin, N. (författare)
  • Maret, E.Karolinska Institutet (författare)
  • Eriksson, M. (författare)
  • Caidahl, Kenneth,1949Karolinska Institutet,Gothenburg University,Göteborgs universitet,Institutionen för medicin,Institute of Medicine(Swepub:gu)xcaike (författare)
  • Sorensson, P.Karolinska Institutet (författare)
  • Sigfridsson, A.Karolinska Institutet (författare)
  • Ugander, M.Karolinska Institutet (författare)
  • Karolinska InstitutetInstitutionen för medicin (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Jacc-Cardiovascular Imaging: Elsevier BV13:12, s. 2530-25421936-878X1876-7591

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy