SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Dahlén Gunnar 1944)
 

Sökning: WFRF:(Dahlén Gunnar 1944) > (2020-2024) > Effect of biofilm f...

Effect of biofilm formation on implant abutments with an anti-bacterial coating: A pre-clinical in vivo study

Almohandes, Ahmed (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology
Abrahamsson, Ingemar, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
Dahlén, Gunnar, 1944 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 3,Institute of Odontology, Section 3
visa fler...
Berglundh, Tord, 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för odontologi, sektion 2,Institute of Odontology, Section 2
visa färre...
 (creator_code:org_t)
2021-03-24
2021
Engelska.
Ingår i: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 32:6, s. 756-766
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives To analyse the long-term effect of plaque formation on implant abutments with an antibacterial coating and the ensuing host response in peri-implant tissues. Materials and methods Four implants were installed in each mandibular premolar region following tooth extraction in six dogs. Three months later, two test abutments with a titanium-bismuth-gallium (Ti-Bi-Ga) coating and two control titanium abutments were connected to the implants on each side of the mandible. After 2 months, ligatures were placed around the implants in one side of the mandible and plaque formation was allowed until the end of the experiment. The ligatures were removed after 4 weeks. Radiographs and microbiological samples were obtained from each implant site during the plaque formation period. Biopsies were obtained 8 months after abutment connection and prepared for histological analysis. Results The analysis did not reveal any statistically significant differences in bone loss, bacterial growth and size of inflammatory lesions between implant units with and without the Ti-Bi-Ga coating. Implant sites exposed to the short period of ligature-induced breakdown demonstrated more pronounced bone loss and bacterial growth than non-ligature sites. Conclusions It is suggested that a Ti-Bi-Ga coating does not prevent biofilm formation on the implant device and does not influence the ensuing host response in the adjacent peri-implant mucosa.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

bone loss
dental implant
gallium
histology
inflammation
peri‐
implant mucositis
peri‐
implantitis
Dentistry
Oral Surgery & Medicine
Engineering

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy