Search: id:"swepub:oai:gup.ub.gu.se/303726" >
Quantification of P...
-
Meltzer, CarinGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
(author)
Quantification of Pulmonary Pathology in Cystic Fibrosis-Comparison Between Digital Chest Tomosynthesis and Computed Tomography.
- Article/chapterEnglish2021
Publisher, publication year, extent ...
-
2021-03-04
-
Oxford University Press (OUP),2021
Numbers
-
LIBRIS-ID:oai:gup.ub.gu.se/303726
-
https://gup.ub.gu.se/publication/303726URI
-
https://doi.org/10.1093/rpd/ncab017DOI
Supplementary language notes
Part of subdatabase
Classification
-
Subject category:ref swepub-contenttype
-
Subject category:art swepub-publicationtype
Notes
-
Digital tomosynthesis (DTS) is currently undergoing validation for potential clinical implications. The aim of this study was to investigate the potential for DTS as a low-dose alternative to computed tomography (CT) in imaging of pulmonary pathology in patients with cystic fibrosis (CF).DTS and CT were performed as part of the routine triannual follow-up in 31 CF patients. Extent of disease was quantified according to modality-specific scoring systems. Statistical analysis included Spearman's rank correlation coefficient (r) and Krippendorff's alpha (α).The median effective dose was 0.14 for DTS and 2.68 for CT. Intermodality correlation was very strong for total score and the subscores regarding bronchiectasis and bronchial wall-thickening (r=0.82-0.91, P<0.01). Interobserver reliability was high for total score, bronchiectasis and mucus plugging (α=0.83-0.93) in DTS.Chest tomosynthesis could be a low-dose alternative to CT in quantitative estimation of structural lung disease in CF.
Subject headings and genre
Added entries (persons, corporate bodies, meetings, titles ...)
-
Gilljam, M
(author)
-
Vikgren, J
(author)
-
Norrlund, R R
(author)
-
Vult von Steyern, K
(author)
-
Båth, Magnus,1974Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences(Swepub:gu)xbatma
(author)
-
Johnsson, Åse (Allansdotter),1966Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology(Swepub:gu)xjohna
(author)
-
Göteborgs universitetInstitutionen för kliniska vetenskaper, Avdelningen för radiologi
(creator_code:org_t)
Related titles
-
In:Radiation protection dosimetry: Oxford University Press (OUP)195:3-4, s. 434-4421742-34060144-8420
Internet link
Find in a library
To the university's database