SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Marasco G.)
 

Sökning: WFRF:(Marasco G.) > GAPS-EUS: a new and...

GAPS-EUS: a new and reliable too or the assessment of basic skills and performance in EUS among endosonography trainees

Hedenström, Per (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Marasco, G. (författare)
Eusebi, L. H. (författare)
visa fler...
Lindkvist, Björn (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
Sadik, Riadh, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
visa färre...
 (creator_code:org_t)
2021-06-09
2021
Engelska.
Ingår i: Bmj Open Gastroenterology. - : BMJ. - 2054-4774. ; 8:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective Endosonography (EUS) is a useful but complex diagnostic modality which requires advanced endoscopy training and guidance by a supervisor. Since learning curves vary among individuals, assessment of the actual competence among EUS trainees is important. Design/methods We designed a novel assessment tool entitled Global Assessment of Performance and Skills in EUS (GAPS-EUS) for assessing skills among EUS trainees. Five quality indicators were marked on a five-grade scale by the supervisor (Observer Score) and by the trainee (Trainee Score). Trainees were included in two high-volume centres (Gothenburg, Sweden, and Bologna, Italy). Outcomes were feasibility, patient safety, reliability, and validity of GAPS-EUS in trainee-performed EUS procedures. Results Twenty-two EUS-trainees were assessed in a total of 157 EUS procedures with a completion rate of 157/157 (100 %) and a patient adverse event rate of 2/157 (1.3 %; gastroenteritis n=1, fever n=1). GAPS-EUS showed a high measurement reliability (Cronbach's alpha coefficient=0.87) and a high interrater reliability comparing the supervisor and the trainee (r=0.83, r(2) =0.69, p<0.001). The construct of GAPS-EUS was verified by comparing low-level and high-level performance procedures and the content validity by recording that the EUS-FNA manoeuvre resulted in a lower score than other aspects of EUS 3.07 (95% CI 2.91 to 3.23) vs 3.51 (95% CI 3.37 to 3.65) (p<0.001). External validity was confirmed via similar findings in both centres. Conclusion GAPS-EUS is an easy-to-use and reliable tool with a recorded high validity for the assessment of competence among trainees in EUS. It can be recommended to centres involved in the education of future endosonographers.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Gastroenterologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Gastroenterology and Hepatology (hsv//eng)

Nyckelord

gastroenterology european-society
endoscopic ultrasound
global
assessment
technical skills
learning-curves
complications
competence
Gastroenterology & Hepatology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy