Sökning: WFRF:(Marasco G.) >
GAPS-EUS: a new and...
GAPS-EUS: a new and reliable too or the assessment of basic skills and performance in EUS among endosonography trainees
-
- Hedenström, Per (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
-
Marasco, G. (författare)
-
Eusebi, L. H. (författare)
-
visa fler...
-
- Lindkvist, Björn (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
-
- Sadik, Riadh, 1963 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
-
visa färre...
-
(creator_code:org_t)
- 2021-06-09
- 2021
- Engelska.
-
Ingår i: Bmj Open Gastroenterology. - : BMJ. - 2054-4774. ; 8:1
- Relaterad länk:
-
https://bmjopengastr...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective Endosonography (EUS) is a useful but complex diagnostic modality which requires advanced endoscopy training and guidance by a supervisor. Since learning curves vary among individuals, assessment of the actual competence among EUS trainees is important. Design/methods We designed a novel assessment tool entitled Global Assessment of Performance and Skills in EUS (GAPS-EUS) for assessing skills among EUS trainees. Five quality indicators were marked on a five-grade scale by the supervisor (Observer Score) and by the trainee (Trainee Score). Trainees were included in two high-volume centres (Gothenburg, Sweden, and Bologna, Italy). Outcomes were feasibility, patient safety, reliability, and validity of GAPS-EUS in trainee-performed EUS procedures. Results Twenty-two EUS-trainees were assessed in a total of 157 EUS procedures with a completion rate of 157/157 (100 %) and a patient adverse event rate of 2/157 (1.3 %; gastroenteritis n=1, fever n=1). GAPS-EUS showed a high measurement reliability (Cronbach's alpha coefficient=0.87) and a high interrater reliability comparing the supervisor and the trainee (r=0.83, r(2) =0.69, p<0.001). The construct of GAPS-EUS was verified by comparing low-level and high-level performance procedures and the content validity by recording that the EUS-FNA manoeuvre resulted in a lower score than other aspects of EUS 3.07 (95% CI 2.91 to 3.23) vs 3.51 (95% CI 3.37 to 3.65) (p<0.001). External validity was confirmed via similar findings in both centres. Conclusion GAPS-EUS is an easy-to-use and reliable tool with a recorded high validity for the assessment of competence among trainees in EUS. It can be recommended to centres involved in the education of future endosonographers.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Gastroenterologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Gastroenterology and Hepatology (hsv//eng)
Nyckelord
- gastroenterology european-society
- endoscopic ultrasound
- global
- assessment
- technical skills
- learning-curves
- complications
- competence
- Gastroenterology & Hepatology
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas