Sökning: WFRF:(Thomeé Roland 1954) >
Validation of an 18...
Validation of an 18-item version of the Swedish Knee Self-Efficacy Scale for patients after ACL injury and ACL reconstruction
-
- Beischer, Susanne (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
-
- Hamrin Senorski, Eric, 1989 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
-
Thomee, P. (författare)
-
visa fler...
-
- Thomeé, Roland, 1954 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
-
visa färre...
-
(creator_code:org_t)
- 2021-10-25
- 2021
- Engelska.
-
Ingår i: Journal of Experimental Orthopaedics. - : Springer Science and Business Media LLC. - 2197-1153. ; 8:1
- Relaterad länk:
-
https://jeo-esska.sp...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose To evaluate the measurement properties of a new version of the Swedish Knee Self-Efficacy Scale (K-SES) in samples of individuals with an anterior cruciate ligament (ACL) injury and after ACL reconstruction. A secondary aim was to translate the new version of K-SES into English in order to prepare for future complete cross-cultural adaptation. Methods The reliability, structural validity, internal consistency and construct validity of the new, 18-item version of the K-SES (K-SES18) were assessed according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist for evaluating methodological quality. The Swedish version of the K-SES18 was translated to English using recommended guidelines. Results The test-retest reliability for the K-SES18 subscale present and the K-SES18 subscale future showed an Interclass Correlation Coefficient (ICC) = 0.92. In addition, the K-SES18 had a Cronbach's alpha ranging from 0.93 to 0.96 for the K-SES18 subscale present and from 0.81 to 0.91 for the K-SES18 subscale future. No floor and ceiling effects were identified for the subscale present or the subscale future of the K-SES18. A factor analysis produced 2 factors of importance; K-SES(18)present and K-SES(18)future. Seven predefined hypotheses were confirmed. Conclusion The K-SES18 has acceptable reliability and validity to assess knee self-efficacy in patients up to 18 months after ACL injury and reconstruction.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
Nyckelord
- Anterior cruciate ligament
- Cross-cultural adaptation
- Patient-reported
- outcome measure
- Psychometrics
- Self-efficacy
- cruciate ligament reconstruction
- physical-activity
- sport
- rehabilitation
- osteoarthritis
- quality
- pain
- predictors
- recovery
- cosmin
- Orthopedics
- Surgery
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas