SwePub
Sök i LIBRIS databas

  Extended search

L773:1745 3690 OR L773:1745 3674 OR L773:1745 3682
 

Search: L773:1745 3690 OR L773:1745 3674 OR L773:1745 3682 > Precision of low-do...

Precision of low-dose CT-based micromotion analysis technique for the assessment of early acetabular cup migration compared with gold standard RSA: a prospective study of 30 patients up to 1 year

Angelomenos, Vasileios (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Mohaddes, Maziar, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Itayem, Raed (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
show more...
Shareghi, Bita (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
show less...
 (creator_code:org_t)
2022-04-22
2022
English.
In: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 93, s. 459-465
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background and purpose - Computed tomography micromotion analysis (CTMA) can be used to determine implant micro-movements using low-dose CT scans. By using CTMA, a non-invasive measurement of joint implant movement is enabled. We evaluated the precision of CTMA in measuring early cup migration. Standard marker-based radiostereometric analysis (RSA) was used as reference. We hypothesised that CTMA can be used as an alternative to RSA in assessing implant micromotions. Patients and methods - We included 30 patients undergoing total hip arthroplasty (THA). Acetabular cup migration at 1 year was measured with RSA and CTMA. To determine the precision of both methods, 20 double examinations (postoperatively) with repositioning of the patients were performed. The precision was calculated from zero by assuming that there was no motion of the prosthesis between the 2 examinations. Results - The precision of RSA ranged from 0.06 to 0.15 mm for translations and 0.21 degrees to 0.63 degrees for rotations. Corresponding values for CTMA were 0.06 to 0.13 mm and 0.23 degrees to 0.35 degrees. A good level of agreement was found between the methods regarding cup migration and rotation at 1 year. Interpretation - The precision of CTMA in measuring acetabular cup migration and rotation is comparable to marker-based RSA. CTMA could possibly thus be used as an alternative method to detect early implant migration.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Keyword

total hip-arthroplasty
radiostereometric analysis
late revision
semiautomated program
computed-tomography
polyethylene wear
tantalum
beads
model
metaanalysis
stability
Orthopedics

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Angelomenos, Vas ...
Mohaddes, Maziar ...
Itayem, Raed
Shareghi, Bita
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Orthopaedics
Articles in the publication
Acta Orthopaedic ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view