SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/317050"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/317050" > Patterns and determ...

  • Holmqvist, JacobGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care (författare)

Patterns and determinants of blood transfusion in intensive care in Sweden between 2010 and 2018: A nationwide, retrospective cohort study

  • Artikel/kapitelEngelska2022

Förlag, utgivningsår, omfång ...

  • 2022-05-31
  • Wiley,2022

Nummerbeteckningar

  • LIBRIS-ID:oai:gup.ub.gu.se/317050
  • https://gup.ub.gu.se/publication/317050URI
  • https://doi.org/10.1111/trf.16942DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:149724255URI

Kompletterande språkuppgifter

  • Språk:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Background Intensive care unit (ICU) patients are transfused with blood products for a number of reasons, from massive ongoing hemorrhage, to mild anemia following blood sampling, combined with bone marrow depression due to critical illness. There's a paucity of data on transfusions in ICUs and most studies are based on audits or surveys. The aim of this study was to provide a complete picture of ICU-related transfusions in Sweden. Methods We conducted a register based retrospective cohort study with data on all adult patient admissions from 82 of 84 Swedish ICUs between 2010 and 2018, as recorded in the Swedish Intensive Care Register. Transfusions were obtained from the SCANDAT-3 database. Descriptive statistics were computed, characterizing transfused and nontransfused patients. The distribution of blood use comparing different ICUs was investigated by computing the observed proportion of ICU stays with a transfusion, as well as the expected proportion. Results In 330,938 ICU episodes analyzed, at least one transfusion was administered for 106,062 (32%). For both red-cell units and plasma, the fraction of patients who were transfused decreased during the study period from 31.3% in 2010 to 24.6% in 2018 for red-cells, and from 16.6% in 2010 to 9.4% in 2018 for plasma. After adjusting for a range of factors, substantial variation in transfusion frequency remained, especially for plasma units. Conclusion Despite continuous decreases in utilization, transfusions remain common among Swedish ICU patients. There is considerable unexplained variation in transfusion rates. More research is needed to establish stronger critiera for when to transfuse ICU patients.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Brynolf, A. (författare)
  • Zhao, J. C.Karolinska Institutet (författare)
  • Halmin, M. (författare)
  • Hollenberg, J.Karolinska Institutet (författare)
  • Martensson, J.Karolinska Institutet (författare)
  • Bell, M.Karolinska Institutet (författare)
  • Block, LindaGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård,Institute of Clinical Sciences, Department of Anesthesiology and Intensive care(Swepub:gu)xblocl (författare)
  • Edgren, G.Karolinska Institutet (författare)
  • Göteborgs universitetInstitutionen för kliniska vetenskaper, Avdelningen för anestesiologi och intensivvård (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Transfusion: Wiley62:6, s. 1188-11980041-11321537-2995

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy