Sökning: WFRF:(Götstedt Julia) >
Evaluation of measu...
Evaluation of measures related to dosimetric uncertainty of VMAT plans
-
- Götstedt, Julia (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för medicinsk strålningsvetenskap,Institute of Clinical Sciences, Department of Medical Radiation Sciences
-
Karlsson, Anna (författare)
-
Bäck, Anna (författare)
-
(creator_code:org_t)
- 2022-12-15
- 2022
- Engelska.
-
Ingår i: Journal of Applied Clinical Medical Physics. - : Wiley. - 1526-9914.
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Dosimetric uncertainty is most often not included in the process of creating and selecting plans for treatment. Treatment planning and the physician's choice of treatment plan is instead often based only on evaluation of clinical goals of the calculated absorbed dose distribution. Estimation of the dosimetric uncertainty could potentially have impact in the process of comparing and selecting volumetric modulated arc therapy (VMAT) plans. In this study, different measures for estimation of dosimetric uncertainty based on treatment plan parameters for plans with similar dose distributions were evaluated. VMAT plans with similar dose distributions but with different treatment plan designs were created using three different optimization methods for each of ten patient cases (tonsil and prostate cancer). Two plans were optimized in Eclipse, one with and one without the use of aperture shape controller, and one plan was optimized in RayStation. The studied measures related to dosimetric uncertainty of treatment plans were aperture-based complexity metric analysis, investigation of modulation level of multi leaf collimator leaves, gantry speed and dose rate, quasi-3D measurements and evaluation of simulations of realistic delivery variations. The results showed that there can be variations in dosimetric uncertainty for treatment plans with similar dose distributions. Dosimetric uncertainty assessment could therefore have impact on the choice of plan to be used for treatment and lead to a decrease in the uncertainty level of the delivered absorbed dose distribution. This study showed that aperture shape complexity had a larger impact on dosimetric uncertainty compared to modulation level of MLC, gantry speed and dose rate.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Nyckelord
- dosimetric uncertainty
- quality assurance
- VMAT
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas