CGM accuracy: Contrasting CE marking with the governmental controls of the USA (FDA) and Australia (TGA): A narrative review

Pemberton, J. S. (författare)
Wilmot, E. G. (författare)
Barnard-Kelly, K. (författare)
visa fler...
Leelarathna, L. (författare)
Oliver, N. (författare)
Randell, T. (författare)
Taplin, C. E. (författare)
Choudhary, P. (författare)
Adolfsson, Peter, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2023-02-05
2023
Engelska.
Ingår i: Diabetes Obesity & Metabolism. - : Wiley. - 1462-8902 .- 1463-1326. ; 25:4, s. 916-939
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The National Institute for Clinical Excellence updated guidance for continuous glucose monitoring (CGM) in 2022, recommending that CGM be available to all people living with type 1 diabetes. Manufacturers can trade in the UK with Conformite Europeenne (CE) marking without an initial national assessment. The regulatory process for CGM CE marking, in contrast to the Food and Drug Administration (FDA) and Australian Therapeutic Goods Administration (TGA) process, is described. Manufacturers operating in the UK provided clinical accuracy studies submitted for CE marking. Critical appraisal of the studies shows several CGM devices have CE marking for wide-ranging indications beyond available data, unlike FDA and TGA approval. The FDA and TGA use tighter controls, requiring comprehensive product-specific clinical data evaluation. In 2018, the FDA published the integrated CGM (iCGM) criteria permitting interoperability. Applying the iCGM criteria to clinical data provided by manufacturers trading in the UK identified several study protocols that minimized glucose variability, thereby improving CGM accuracy on all metrics. These results do not translate into real-life performance. Furthermore, for many CGM devices available in the UK, accuracy reported in the hypoglycaemic range is below iCGM standards, or measurement is absent. We offer a framework to evaluate CGM accuracy studies critically. The review concludes that FDA- and TGA-approved indications match the available clinical data, whereas CE marking indications can have discrepancies. The UK can bolster regulation with UK Conformity Assessed marking from January 2025. However, balanced regulation is needed to ensure innovation and timely technological access are not hindered.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Nyckelord

accuracy
CE marking
continuous glucose monitoring (CGM)
type 1
diabetes
type 2 diabetes
hybrid closed-loop
glucose monitoring-system
insulin delivery
adults
multicenter
performance
adolescents
management
consensus
children
Endocrinology & Metabolism

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy