SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sällsten Gerd 1952)
 

Sökning: WFRF:(Sällsten Gerd 1952) > (2020-2024) > The variability of ...

The variability of arsenic in blood and urine of humans

Ellingsen, D. G. (författare)
Weinbruch, S. (författare)
Sällsten, Gerd, 1952 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för samhällsmedicin och folkhälsa,Institute of Medicine, School of Public Health and Community Medicine
visa fler...
Berlinger, B. (författare)
Barregård, Lars, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för samhällsmedicin och folkhälsa,Institute of Medicine, School of Public Health and Community Medicine
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Journal of Trace Elements in Medicine and Biology. - 0946-672X. ; 78
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Humans are exposed to inorganic and organic arsenic. The total arsenic (As) concentration in urine is a commonly used biomarker of exposure. However, little is known about variability of As in biological fluids and the diurnal variation of As excretion.Objectives: Main objectives were to assess the variability of As in urine, plasma (P-As), whole blood (B-As), and the blood cell fraction (C-As), and to assess diurnal variation of As excretion. Methods: Six urine samples were collected at fixed times during 24 h on two different days around one week apart among 29 men and 31 women. Blood samples were collected when the morning urine samples were delivered. The intra-class correlation coefficient (ICC) was calculated as the ratio of the between-individuals variance to the total observed variance.Results: Geometric mean (GM) 24 h urinary excretions of As (U-As24 h) were 41 and 39 mu g/24 h on the two days of sampling. Concentrations of B-As, P-As and C-As were highly correlated with U-As24 h and As in first void morning urine. No statistically significant differences were observed for the urinary As excretion rate between the different sampling times. A high ICC was observed for As in the cellular blood fraction (0.803), while ICC for first morning urine corrected for creatine was low (0.316).Conclusions: The study suggests that C-As is the most reliable biomarker for use in exposure assessment of individual exposure. Morning urine samples have low reliability for such use. No apparent diurnal variation was observed in the urinary As excretion rate.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Nyckelord

Arsenic
24 h urine
Intraclass correlation
Diurnal variation
reference intervals
exposure
excretion
biomarkers
speciation
samples
areas
Biochemistry & Molecular Biology
Endocrinology & Metabolism

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy