SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1397 3142
 

Sökning: L773:1397 3142 > Shear wave elastogr...

  • Cetinic, IvanGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences (författare)

Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow-up of pediatric liver grafts

  • Artikel/kapitelEngelska2023

Förlag, utgivningsår, omfång ...

  • 2023

Nummerbeteckningar

  • LIBRIS-ID:oai:gup.ub.gu.se/330960
  • https://gup.ub.gu.se/publication/330960URI
  • https://doi.org/10.1111/petr.14591DOI

Kompletterande språkuppgifter

  • Språk:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Background: It is unknown how shear wave dispersion (SWD) is displayed in pediatric liver transplant recipients and not fully elucidated how ultrasound shear wave elastography (2D-SWE) display within this cohort, which is important to determine to improve noninvasive surveillance of these patients. The study aimed to compare SWE and SWD values with histopathology in pediatric liver recipients.Methods: Forty-eight pediatric liver recipients were examined with SWE in conjunction with an elective liver biopsy (clinically without complication). Additionally, SWD values were measured in 21 children. SWE and SWD values were compared to histologically determined fibrosis graded as none-to-mild (F0-1) and moderate-to-severe (F2-4), and inflammation graded as low (grade 0-1) and high (grade 2-4).Results: Two children were excluded due to SWE IQR/median > 30% kPa. The mean age across 46 included patients was 10.9 years (range 1.4-18). The number of patients and median (range) SWE value (kPa) for each stage of fibrosis were: F0-1 [n = 23; 5.8 (3.2-16.1)], F2 [n = 22; 6.0 (4.5-25.9)], F3 [n = 1; 33.3], and F4 [n = 0]. Significantly higher SWE values and greater variability were registered in F2-4 vs. F0-1 (p = .05). Grade of fibrosis correlated weakly to SWE values (r = .3; p = .05), but not to SWD values (r = .2; p = .27). In patients with low-grade inflammation, median SWD was 13.7 m/s KHz (10.7-17.6). Only one patient had high-grade inflammation.Conclusions: Uncomplicated transplanted liver grafts in a small pediatric cohort revealed slightly increased SWE and SWD values compared to previously reported values in healthy children. This likely reflect both the fibrotic and inflammatory elements in the grafts; however, other confounders impacting the liver's viscoelastic properties are also probable factors.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • de Lange, Charlotte,1963Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences(Swepub:gu)xdelch (författare)
  • Boström, HåkanGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences (författare)
  • Ekvall, N. (författare)
  • Bennet, W. (författare)
  • Lagerstrand, Kerstin MGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences(Swepub:gu)xlagke (författare)
  • Hebelka, Hanna,1977Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology(Swepub:gu)xhebha (författare)
  • Göteborgs universitetInstitutionen för kliniska vetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Pediatric Transplantation27:71397-3142

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy