SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ruiz Ronald F. Garcia)
 

Sökning: WFRF:(Ruiz Ronald F. Garcia) > Voltage scanning an...

Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment

Athanasakis-Kaklamanakisa, Michail (författare)
Reilly, Jordan R. (författare)
Koszorus, Agota (författare)
visa fler...
Wilkins, Shane G. (författare)
Lalanne, Louis (författare)
Geldhofb, Sarina (författare)
Nichols, Miranda, 1997 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för fysik (GU),Department of Physics (GU)
Wang, Quanjun (författare)
van den Borne, Bram (författare)
Chorlton, David (författare)
Cocolios, Thomas E. (författare)
Flanagan, Kieran T. (författare)
Ruiz, Ronald F. Garcia (författare)
de Groote, Ruben (författare)
Hanstorp, Dag, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för fysik (GU),Department of Physics (GU)
Neyens, Gerda (författare)
Smith, Andrew J. (författare)
Vernon, Adam R. (författare)
Yang, Xiaofei F. (författare)
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - 0168-583X .- 1872-9584. ; 541, s. 86-89
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To optimize the performance of the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at CERN-ISOLDE, technical upgrades are continuously introduced, aiming to enhance its sensitivity, precision, stability, and efficiency. Recently, a voltage-scanning setup was developed and commissioned at CRIS, which improved the scanning speed by a factor of three as compared to the current laser-frequency scanning approach. This leads to faster measurements of the hyperfine structure for systems with high yields (more than a few thousand ions per second). Additionally, several beamline sections have been redesigned and manufactured, including a new field-ionization unit, an electrostatic bend with a larger deflection angle, and improved ion optics. The beamline upgrades are expected to yield an improvement of at least a factor of 5 in the signal-to-noise ratio by avoiding the use of high-power lasers (which yield non-resonantly produced ions) and providing time-of-flight separation between the resonant ions and the collisional background.

Ämnesord

NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)

Nyckelord

CRIS
Collinear resonance ionization spectroscopy
Laser spectroscopy
Voltage scanning
ISOLDE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy