SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(De Backer Ole)
 

Sökning: WFRF:(De Backer Ole) > (2020-2024) > Transcatheter or su...

Transcatheter or surgical aortic valve implantation: 10-year outcomes of the NOTION trial.

Thyregod, Hans Gustav Hørsted (författare)
Jørgensen, Troels Højsgaard (författare)
Ihlemann, Nikolaj (författare)
visa fler...
Steinbrüchel, Daniel Andreas (författare)
Nissen, Henrik (författare)
Kjeldsen, Bo Juel (författare)
Petursson, Petur, 1973 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine
De Backer, Ole (författare)
Olsen, Peter Skov (författare)
Søndergaard, Lars (författare)
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: European heart journal. - 1522-9645.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Transcatheter aortic valve implantation (TAVI) has become a viable treatment option for patients with severe aortic valve stenosis across a broad range of surgical risk. The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize patients at lower surgical risk to TAVI or surgical aortic valve replacement (SAVR). The aim of the present study was to report clinical and bioprosthesis outcomes after 10 years.The NOTION trial randomized 280 patients to TAVI with the self-expanding CoreValve (Medtronic Inc.) bioprosthesis (n = 145) or SAVR with a bioprosthesis (n = 135). The primary composite outcome was the risk of all-cause mortality, stroke, or myocardial infarction. Bioprosthetic valve dysfunction (BVD) was classified as structural valve deterioration (SVD), non-structural valve dysfunction (NSVD), clinical valve thrombosis, or endocarditis according to Valve Academic Research Consortium-3 criteria. Severe SVD was defined as (i) a transprosthetic gradient of 30mmHg or more and an increase in transprosthetic gradient of 20mmHg or more or (ii) severe new intraprosthetic regurgitation. Bioprosthetic valve failure (BVF) was defined as the composite rate of death from a valve-related cause or an unexplained death following the diagnosis of BVD, aortic valve re-intervention, or severe SVD.Baseline characteristics were similar between TAVI and SAVR: age 79.2 ± 4.9 years and 79.0 ± 4.7 years (P = .7), male 52.6% and 53.8% (P = .8), and Society of Thoracic Surgeons score < 4% of 83.4% and 80.0% (P = .5), respectively. After 10 years, the risk of the composite outcome all-cause mortality, stroke, or myocardial infarction was 65.5% after TAVI and 65.5% after SAVR [hazard ratio (HR) 1.0; 95% confidence interval (CI) 0.7-1.3; P = .9], with no difference for each individual outcome. Severe SVD had occurred in 1.5% and 10.0% (HR 0.2; 95% CI 0.04-0.7; P = .02) after TAVI and SAVR, respectively. The cumulative incidence for severe NSVD was 20.5% and 43.0% (P < .001) and for endocarditis 7.2% and 7.4% (P = 1.0) after TAVI and SAVR, respectively. No patients had clinical valve thrombosis. Bioprosthetic valve failure occurred in 9.7% of TAVI and 13.8% of SAVR patients (HR 0.7; 95% CI 0.4-1.5; P = .4).In patients with severe AS and lower surgical risk randomized to TAVI or SAVR, the risk of major clinical outcomes was not different 10 years after treatment. The risk of severe bioprosthesis SVD was lower after TAVR compared with SAVR, while the risk of BVF was similar.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy