SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nordeman Lena Margareta)
 

Sökning: WFRF:(Nordeman Lena Margareta) > (2020-2024) > Self-assessment usi...

Self-assessment using 30-second chair stand test for patients with knee osteoarthritis - an intra- and inter-rater reliability study

Ho, Chan-Mei (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
Thorstensson, Carina (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
Nordeman, Lena Margareta (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: EUROPEAN JOURNAL OF PHYSIOTHERAPY. - 2167-9169 .- 2167-9177.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: We aimed to evaluate the intra-rater reliability in 30-second chair stand test (30CST) as a self-test, and the inter-rater reliability comparing a self-test with a physiotherapist-assessed 30CST for patients with knee osteoarthritis (KOA). The second purpose was to evaluate the classification ability of the 30CST as self-test to distinguish between reduced physical function and normal function. Methods: Patients with KOA performed two self-tests of 30CST at home and thereafter a physiotherapist assessed the patient. Absolute agreements were presented with intraclass correlation coefficient (ICC), 95% confidence interval (CI) and standard error of measurement (SEM). Post-hoc analyses were conducted to calculate minimal detectable change (MDC). The classification ability was analysed with receiver operating characteristic (ROC)-curves and area under the ROC-curve (AUC). The significance level was p < 0.05. Results: In total, 114 followed the protocol. Intra-rater and inter-rater reliability were good (ICC 0.97, CI 0.95-0.99, SEM 0.89 and ICC 0.81, CI 0.72-0.87, SEM 2.29 respectively). MDC were 2.5 stands when comparing self-test results individually and 0.23 on a group level. The MDC between self-tests and physiotherapist assessment were 6.4 stands for individual comparison and 0.59 for group comparison. The self-test was 80% likely to detect reduced physical function compared to a physiotherapist assessing physical function with 30CST (AUC = 0.79-0.80). Conclusions: The results indicate that 30CST can be a reliable self-assessment of physical function in lower extremities for patients with KOA. These findings can be useful in areas such as self-screening for reduced physical function, self-assessment in digital physiotherapy, and as measurement in research projects.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences (hsv//eng)

Nyckelord

self-assessment
physical function
physiotherapy
knee osteoarthritis
digital healthcare
minimal detectable change
cut-off value

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ho, Chan-Mei
Thorstensson, Ca ...
Nordeman, Lena M ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
Artiklar i publikationen
EUROPEAN JOURNAL ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy