Electroacoustic evaluation of the bone conduction transducer B250 for vestibular and hearing diagnostics in comparison with Radioear B71 and B81

Fredén Jansson, Karl-Johan, 1988 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Håkansson, Bo, 1953 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Persson, Ann-Charlotte, 1970 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology,University of Gothenburg,Västra Götalandsregionen,Region Västra Götaland
visa fler...
Verrecchia, Luca, 1971 (författare)
Karolinska Institutet
Reinfeldt, Sabine, 1978 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: INTERNATIONAL JOURNAL OF AUDIOLOGY. - 1499-2027 .- 1708-8186.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ObjectiveThe objective is to evaluate the electroacoustic performance of the B250 transducer and to compare it with the two most widely used audiometric transducers B71 and B81.DesignThe electroacoustic performance was evaluated in terms of sensitivity level, distortion, maximum hearing level and electrical impedance.Study sampleSix B250 prototype transducers were evaluated and compared with published data of B71 and B81 together with complementary measurements of maximum hearing level at 125 Hz and phase of electrical impedance. Differences in reference equivalent threshold vibratory force levels were estimated by comparing hearing threshold measurements of 60 healthy ears using B81 and B250.ResultsB250 has approximately 27 dB higher sensitivity levels than both B71 and B81 at 250 Hz and can generate higher maximum hearing level at low frequencies: 11.8 to 35.8 dB (125-1000 Hz) higher than B71, and 1.4 to 18.6 dB (125-750 Hz) higher than B81. The maximum average difference in reference threshold force levels was 13.5 +/- 8.7 dB higher for B250 at 250 Hz compared to B81.ConclusionsB250 can produce higher output force with less distortion than B71 and B81, especially at 125 and 250 Hz, which could possibly improve low frequency investigations of the audio-vestibular system.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)

Nyckelord

Audiometry
bone conduction
vestibular
dizziness
vertigo
Audiometry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy