SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Karlsson Jón)
 

Sökning: WFRF:(Karlsson Jón) > (2005-2009) > Biodegradable and m...

Biodegradable and metallic interference screws in anterior cruciate ligament reconstruction surgery using hamstring tendon grafts: prospective randomized study of radiographic results and clinical outcome

Laxdal, Gauti, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Kartus, Jüri, 1955 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Eriksson, Bengt I., 1946 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa fler...
Faxén, Eva (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Sernert, Ninni, 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Karlsson, Jón, 1953 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2017-08-30
2006
Engelska.
Ingår i: The American Journal of Sports Medicine. - : SAGE Publications. - 0363-5465 .- 1552-3365. ; 34:10, s. 1574-80
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: The use of biodegradable screws in anterior cruciate ligament reconstruction has grown in popularity. PURPOSE: To compare the clinical and radiographic results in arthroscopically assisted anterior cruciate ligament reconstruction using 4-strand hamstring tendon grafts and either metallic (metal group) or biodegradable (PLLA group) interference screw fixation. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A randomized series of 77 patients, all with a unilateral anterior cruciate ligament rupture, was included in the study. The preoperative assessments in both groups were similar in gender, Tegner activity level, Lysholm score, KT-1000 arthrometer measurements, and single-legged hop test results. In both groups, interference screw fixation of the graft was used at both ends, and 68 of 77 (88%) patients returned for a radiographic examination at 6 and 24 months, respectively. RESULTS: At follow-up, no significant differences were found between the 2 groups in KT-1000 arthrometer laxity measurements, Tegner activity level, or Lysholm score. The PLLA group had a significantly better outcome in the single-legged hop test and the final International Knee Documentation Committee classification (P = .007 and P = .03, respectively). At 6 and 24 months after the index operation, the PLLA group displayed significantly larger drill holes on the radiographs than did the metal group on both the tibial (8.1 vs 6.6 mm at 6 months [P = .0007]; 6.0 vs 3.2 mm at 24 months [P < .0001]) and femoral sides (7.8 vs 5.6 mm at 6 months [P < .0001]; 6.3 vs 1.9 mm at 24 months [P < .0001]). CONCLUSION: There were significantly larger radiographically visible drill holes on both the tibial and femoral sides in the PLLA group compared with the metal group at 6 and 24 months. Clinical examination at 2 years revealed no major differences between the groups. The larger drill holes in the PLLA group did not correlate with inferior clinical results.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

*Absorbable Implants
Adolescent
Adult
Analysis of Variance
Anterior Cruciate Ligament/injuries/radiography/*surgery
Arthroplasty/*instrumentation/methods
Arthroscopy
*Bone Screws
Female
Humans
*Lactic Acid
Male
*Metals
Middle Aged
*Polymers
Tendons/*transplantation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy